A ladder inspection checks six structural items per ladder and rolls them into a score, and its recurring failure is treating that score as the verdict. A ladder with one failed stile or a broken locking mechanism is not eighty-three percent safe, it is out of service, and the inspection only does its job when a single failed item ends the assessment rather than being averaged into a passing percentage.

KnowSafeInspectionSAF-025Pinned in navigation37 fields across 3 sectionsFull researchSee the form

Reviewed by Siddarth SinghCSPLast reviewed 16 August 2026

Basis
OSHA 1910.23, CSA Z11
Workspace
KnowSafe
Form type
Inspection
Completed by
Ladder owner or supervisor, monthly and before first use
Feeds
Asset register; CAPA on any fail

The short version

  • The inspection is asset-specific: each ladder gets its own row, its own six condition items and its own Result, not a shared judgement for the fleet.
  • Score Percent excludes N/A items from the denominator, which means a ladder can show a high score while sitting one failed item away from tag-out; the Result field, not the percentage, is the decision.
  • Duty rating (domestic, trade, industrial) is recorded as a fact about the ladder, not a judgement about whether it is the right ladder for the task it is about to do.
  • Fixed ladders are inspected on the same form as portable ones but carry separate construction requirements under OSHA 1910.23(c), and a form that treats them identically misses that distinction.
  • A worn or faded label is not a cosmetic defect. It removes the duty rating information the next user depends on, and CSA Z11 treats legibility as part of the ladder's condition.

What this is

What is a ladder inspection?

What is a ladder inspection?

A ladder inspection is a structured check of one ladder asset against a fixed set of condition items: the stiles, rungs, feet, locking mechanism, label and any modification or repair. It concludes in a pass, conditional pass or fail, and a failed ladder is tagged and removed from service immediately rather than left to the next round.

Who should carry out a ladder inspection?

The ladder owner or a supervisor, and either way someone competent to recognise a structural defect rather than someone formally qualified as an inspector. Competence here means knowing what a cracked stile or a worn locking cam looks like, not holding a certificate in ladder assessment.

What happens when a ladder fails inspection?

It is tagged and removed from service before the inspector leaves the area, not scheduled for removal later. A Finding is raised against the asset, and where a repair or replacement is needed that finding should carry through to a CAPA record so the ladder does not quietly reappear in use before it is fixed.

Scope

When is a ladder inspection required?

This inspection is a periodic and pre-use condition check of a specific ladder asset. It is not a decision about whether a ladder is the right access method for a task, and it is not a general area walkthrough.

Use this template when

  • The routine periodic round is due, at the interval set in your programme
  • A ladder is being used for the first time or returned to service after repair
  • A report of a drop, impact or other occurrence that could have damaged the ladder
  • A follow-up round confirming a previously tagged ladder was repaired and is safe to return
  • A specific ladder asset needs its own auditable record, distinct from a general area inspection

Do not use it for

  • Fall Arrest Equipment Inspection, which covers the harness and lanyard used when working from a fixed ladder, not the ladder itself.
  • A work-at-height risk assessment, which decides whether a ladder is the right access method for the task at all.
  • General Workplace Inspection, a broad walkthrough covering common area hazards rather than one asset's condition.
  • Housekeeping Inspection, which checks that the area around the ladder is clear, not the ladder itself.
  • A ladder training or competency record, which establishes the user was instructed in safe use rather than that the equipment is sound.

Compliance mapping

Which OSHA 1910.23 requirements does this satisfy?

OSHA sets the duty to inspect and the consequence of finding a defect; CSA Z11 sets what the ladder itself must be built and labelled to. Neither prescribes the inspection form, which is why the form's own logic, one fail ends it, carries the actual defensibility.

ClauseRequirementWhere it lands
OSHA 1910.23(a)Ladders maintained free of corrosion and structural defect, used only for their designed purposeLadders
OSHA 1910.23(b)(11)Portable ladders inspected by a competent person for visible defects on a periodic basis and after any occurrence that could affect safe useLadders
OSHA 1910.23(b)A ladder with a structural defect withdrawn from service and tagged or marked to identify it as defectiveLadders
OSHA 1910.23(c)Fixed ladders subject to separate construction and condition requirements from portable laddersLadders
CSA Z11Duty rating and identification marking requirements for portable laddersLadders
OSHA 1910.22(d)Walking-working surfaces, including means of access, inspected regularly and defects corrected before further useResult

What it does not cover

  • Fall Arrest Equipment Inspection, which covers the harness and lanyard used when working from a fixed ladder or at height, not the ladder itself.
  • A work-at-height risk assessment, which decides whether a ladder is the right access method for the task, and belongs to the risk assessment domain rather than an equipment check.
  • General Workplace Inspection, a broad walkthrough covering common area hazards rather than the condition of one asset.
  • Scaffold inspection, a distinct instrument under a different construction standard when the access method is a scaffold rather than a ladder.
  • A ladder training or competency record, which establishes the user was instructed in safe use, and sits in the training domain rather than the equipment's own condition record.

Global

Ladder Inspection requirements by country

The duty to inspect a ladder exists across regimes, but only some name a competent person, a fixed interval, or an explicit hierarchy that puts a ladder below other access methods.

United States

OSHA 1910.23(b)(11)

Inspection by a competent person on a periodic basis and after any occurrence that could affect safe use.

Enforcement runs against continued use of a ladder with a known defect, not against the absence of a written inspection schedule.

Canada

CSA Z11, referenced into provincial OHS regulation

Sets construction, duty rating and labelling; provinces adopt it by reference so it becomes enforceable in that jurisdiction.

The duty rating label on the ladder is not cosmetic; it is the evidence the ladder was rated for the load it is carrying.

United Kingdom

Work at Height Regulations 2005, reg.4 and Schedule 6

Ladders permitted only where a risk assessment shows their use is low-risk and short-duration, subject to a pre-use check.

An inspection record without an accompanying justification for choosing a ladder over another access method invites scrutiny.

How to complete it

How to complete a ladder inspection, step by step

The six condition items are is-or-isn't judgements a checklist can hold well. What the checklist does not hold is the severity call underneath a technically-passing item, and the follow-through once one item fails.

One structural fail ends the assessment

Stiles, rungs, feet and the locking mechanism are load-bearing or fall-preventing elements. A fail on any one of them should set the Result to Fail regardless of what the other five items score, because there is no conditional pass for a structural criterion.

Treat an illegible label as a real defect

The label carries the CSA Z11 duty rating, the information the next user relies on to know the ladder's safe working load. A label faded past reading removes that information even though the ladder may be structurally sound, and it should score as a fail, not a cosmetic note.

Match the duty rating to the task, not just record it

Duty Rating records a fact about the asset, not whether it suits the job. A domestic-duty stepladder can pass inspection while being wrong for an industrial task; the mismatch belongs in equipment selection, and a noticing inspector should flag it in the notes.

Close the loop on tag-out, not just the fail

A Fail result that does not also confirm the ladder was physically tagged and removed leaves a known defect in circulation with a paper record saying otherwise. The Finding ID exists so the tag-out has a record beyond the inspector's memory of having done it.

What auditors find

Most common ladder inspection findings

Ladder inspection findings recur less around whether the form was completed and more around what happens between a fail on the form and the ladder actually leaving service.

FindingClauseWhat fixes it
A structural item is scored Fail but the overall Result is recorded as Pass with conditions.OSHA 1910.23(b)Any fail on stiles, rungs, feet or the locking mechanism forces the Result to Fail; there is no conditional pass for a structural criterion.
Label scored Pass because the ladder is otherwise sound, even though the duty rating can no longer be read.CSA Z11Score Label Legible on whether the duty rating can actually be read, not on the ladder's general condition.
Result recorded as Fail with no Finding ID and no confirmed tag-out.OSHA 1910.23(b)Require the tag-out field whenever Result is Fail; a fail without a linked finding is an open defect with no owner.
A fixed ladder is inspected against the same items as portable stock, with no allowance for its own requirements.OSHA 1910.23(c)Route fixed ladders through condition items that reflect their own construction, not the portable ladder checklist alone.
No inspection is raised after a reported drop or impact to a ladder.OSHA 1910.23(b)(11)Use the Post incident inspection type to force a fresh check whenever an occurrence could have affected the ladder.
Next Inspection Due left blank, so the asset has no forward date driving the next round.OSHA 1910.22(d)Populate Next Inspection Due at closeout so the ladder reappears on the schedule rather than depending on memory.

Case in point

Case in point: the ladder that passed on paper

A warehouse's monthly round inspected a fibreglass extension ladder used for order picking above head height. All six items were marked Pass and the Result was Pass. Three weeks later a picker felt the ladder flex under load and reported it. Closer inspection found a hairline crack along a stile rivet line, visible only with the ladder fully extended under load, not collapsed against a rack for inspection.

The checklist had been followed correctly, with the ladder collapsed in storage because extending it indoors during a round was awkward. The fix was not a new form item; it was an instruction, now attached to the Ladders section, that stiles and rungs must be checked at working length, since a stress crack under load does not always show collapsed.

The template

The template, field by field

The form exactly as it installs. Every field, option, score and conditional rule is editable, and the links to other templates come with it.

37fields
3 sections
Reference
SAF-025
Archetype
Inspection
Record ID
INSP-2026-000
Scoring
Pass or fail per ladder
Direction
High is good
Singleton
No
Basis
OSHA 1910.23, CSA Z11
Links
Links Asset; feeds CAPA
Tags
Inspection, Height
Sections
3
Fields
37
Follow up fields
6
Repeating sections
1
Links out
4
Field typesOwn ID, generated on saveCase thread and parentPick list from a registryLinked to another templateFollow up, dashed outlineScored

Header

7 fields
Text

Inspection ID*

Generated on save

Auto sequence. Format INSP-2026-00000.

The record's own ID. Other templates point at this value.

Single Choice

Status*

Scored

Drives who this goes to next.

  • Planned2 pts
  • In progress2 pts
  • Complete3 pts
  • Deferred0 pts
  • Open0 pts
  • Closed3 pts
  • Overdue0 pts
Date & Time

Date and Time*

Single Choice

Inspection Type*

Scheduled, unscheduled, follow up or post incident.

ScheduledUnscheduledFollow upPost incident
Pick List

Site*

From FDN-001 Site NameFilter: Status is Active
Text

Site ID*

Linked

Format SITE-000.

Links to FDN-001 Site ID

Info

One Row Per Ladder

Add a row for each ladder. Anything that fails is tagged and removed from service before you leave the area.

Ladders

Repeats15 fields
Pick List

Ladder*

From FDN-002 Asset NameFilter: Type is ladder, Site matches
Text

Asset ID*

Linked

Format AST-0000.

Links to FDN-002 Asset ID

Single Choice

Ladder Type*

Step ladderExtension ladderPlatform ladderFixed ladder
Text

Location*

Single Choice

Duty Rating

Optional
DomesticTradeIndustrial
Single Choice

Stiles Undamaged*

Scored
  • Pass2 pts
  • Partial1 pt
  • Fail0 pts
  • N/Aexcluded from denominator
Single Choice

Rungs Secure And Clean*

Scored
  • Pass2 pts
  • Partial1 pt
  • Fail0 pts
  • N/Aexcluded from denominator
Single Choice

Feet Present And Grippy*

Scored
  • Pass2 pts
  • Partial1 pt
  • Fail0 pts
  • N/Aexcluded from denominator
Single Choice

Locking Mechanism Works*

Scored
  • Pass2 pts
  • Partial1 pt
  • Fail0 pts
  • N/Aexcluded from denominator
Single Choice

Label Legible*

Scored
  • Pass2 pts
  • Partial1 pt
  • Fail0 pts
  • N/Aexcluded from denominator
Single Choice

No Modifications Or Repairs*

Scored
  • Pass2 pts
  • Partial1 pt
  • Fail0 pts
  • N/Aexcluded from denominator
Single Choice

Result*

Scored
  • Pass3 pts
  • Pass with conditions2 pts
  • Fail0 pts
File Upload

Photo

OptionalShows if Result equals Fail
Single Choice

Tagged And Removed From Service

OptionalScoredShows if Result equals Fail
  • Yes2 pts
  • No0 pts
  • N/Aexcluded from denominator
Text

Finding ID

OptionalLinkedShows if Result equals Fail

Links to FDN-015 Finding ID

Result

15 fields
Numeric Answer

Items Assessed*

Excludes anything marked N/A.

Numeric Answer

Items Failed*

Numeric Answer

Score Percent*

Scored

Calculated on submission. High is good. N/A items leave the denominator.

Single Choice

Result Band*

Scored
  • Pass3 pts
  • Caution1 pt
  • Fail0 pts
Numeric Answer

Completeness Percent*

How much of the template was actually answered. A high score on a half completed form is not a high score.

Numeric Answer

Findings Raised

Optional
Single Choice

Highest Severity Found

OptionalScored
  • Observation3 pts
  • Minor2 pts
  • Major0 pts
Single Choice

Action Required*

Scored

Raise the action record, then enter its reference here.

  • No2 pts
  • Yes0 pts
Single Choice

Priority

OptionalScoredShows if Action Required equals Yes
  • High0 pts
  • Medium1 pt
  • Low3 pts
Text

CAPA ID

OptionalLinkedShows if Action Required equals Yes

Format CAPA-2026-00000.

Links to FDN-014 CAPA ID

Users

Action Owner

OptionalShows if Action Required equals Yes
Date & Time

Next Inspection Due

Optional
Text

Notes

Optional
Users

Inspected By*

Signature

Signature*

SAF-025 · record IDs look like INSP-2026-000 · Links Asset; feeds CAPA

Open in Knowella

Run it with agents

From a document you fill in to a programme that runs itself

The form catches a cracked stile. What actually fails is the routing: a ladder tagged on paper but never physically pulled, or a repair nobody confirms before the ladder goes back on the floor.

KnowSafe

Holds the ladder register and inspection cadence, flags overdue or post-incident rounds, and keeps the tag-out and finding linked to the same asset.

KnowMaintain

Turns a Fail and its Finding ID into a work order or CAPA, and confirms the repair before the ladder returns to the pick list.

KnowTrain

Ties the competent-person requirement to who is actually qualified to sign off the inspection, rather than whoever is nearest.

Ella
Ella

Watches for a Fail result that is not followed by a tag-out or CAPA reference, and raises it rather than waiting for the next round to notice.

This template lives in KnowSafe — safety and compliance. Incidents, hazards, permits, inspections and the critical controls behind them.

Meet KnowSafe→

Glossary

Ladder Inspection definitions and key terms

Duty rating
The load classification, domestic, trade or industrial, that sets the maximum safe working load a ladder is designed to carry.
Stiles
The two vertical side rails of a ladder that carry its structural load; damage here is a structural, not cosmetic, defect.
Competent person
Someone with the knowledge and experience to recognise a ladder defect, not necessarily someone formally qualified as an inspector.
Tag-out
The physical marking and removal from service of a ladder found unsafe, distinct from simply recording the fault on the form.
Working length
The fully extended length of the ladder in use, as distinct from its stored length; some defects only appear under this condition.

FAQ

Frequently asked questions about ladder inspection

How often should a ladder be inspected?+

Monthly at minimum, and again before first use of any ladder, whether newly registered or returned from repair. An occurrence, a drop, an impact, or a report of flexing under load should trigger an inspection outside that schedule rather than waiting for the next round.

Who can carry out a ladder inspection?+

The ladder owner or a supervisor, competent in recognising a structural defect. Competence here is about knowing what a cracked stile or worn locking cam looks like, not about holding a formal inspection qualification.

Does one failed item fail the whole ladder?+

Yes. Stiles, rungs, feet and the locking mechanism are structural or fall-preventing elements, and a fail on any single one of them should set the Result to Fail regardless of what the other items score.

What happens when a ladder fails?+

It is tagged and removed from service immediately, not scheduled for removal. A Finding is raised, and where repair is needed the record should carry through to a CAPA so the ladder cannot quietly return to use unrepaired.

Why does duty rating matter if the ladder passed inspection?+

A pass records that the ladder is structurally sound, not that it is the right ladder for the task. A domestic-duty stepladder can pass inspection and still be the wrong choice for an industrial load, and that mismatch belongs in equipment selection rather than the condition check.

Do fixed ladders need the same inspection as portable ones?+

No. Fixed ladders are subject to separate construction requirements under OSHA 1910.23(c), and an inspection that applies the portable ladder checklist without adjustment misses features specific to a fixed installation.

Keep going

Related templates and programmes

Siddarth Singh

Written and reviewed by

Siddarth Singh

Founder & Chief Executive Officer, Knowella

Certified Safety Professional and industrial and systems engineer with more than a decade inside food supply chain, freight and manufacturing operations. This page was written against the current text of the standards it cites, not against secondary summaries of them.

  • Certified Safety Professional (CSP), Board of Certified Safety Professionals
  • MBA, University of Chicago Booth School of Business
  • MS and BS, The Ohio State University, Industrial and Systems Engineering
  • Six Sigma Black Belt
Verify with BCSP →

Sources and last review. Reviewed 16 August 2026 against:

  • OSHA 1910.23 — Ladders
  • OSHA 1910.22 — General requirements, walking-working surfaces
  • CSA Z11 — Portable ladders
  • Work at Height Regulations 2005 (UK), reg.4 and Schedule 6

This page is general guidance, not legal advice. Confirm requirements with your jurisdiction’s regulator.