A zoning record classifies areas where flammable dust, vapour or gas can form an explosive atmosphere, and sets what equipment may enter each zone. Its recurring failure is its shelf life: zones are assigned once at installation, and the record is rarely revisited when a new silo or a different solvent changes what is actually being released, so the equipment on site stops matching the zone it stands in.

KnowEnviroAssessmentENV-05047 fields across 6 sectionsFull researchSee the form

Reviewed by Siddarth SinghCSPLast reviewed 16 August 2026

Basis
ISO 45001 cl.6.1.2
Workspace
KnowEnviro
Form type
Assessment
Review trigger
Installation, and any change to process, substance or ventilation
Feeds
Equipment purchasing, hot work permits, contractor briefings

The short version

  • Zoning classifies persistence and extent of an explosive atmosphere, not its consequence. A small zone 0 and a large zone 22 can each be correctly classified and still both demand serious control.
  • The zone drives equipment selection, not the other way round. An equipment purchase made before the zone is known routinely turns out to be the wrong category once the classification catches up with it.
  • Ordinary materials create zones as readily as chemical plant does. Flour, sugar, milk powder and cleaning solvent all generate dust or vapour atmospheres that a food or logistics site can easily assume do not apply to them.
  • A zoning record without a change trigger goes stale silently. Nothing stops equipment being installed against last year's classification once the process it was classified for has moved on.

What this is

What is an explosive atmosphere zoning record?

What is an explosive atmosphere zoning record?

A record that identifies where flammable dust, vapour or gas can form an explosive atmosphere with air, classifies the extent and likelihood of that atmosphere into zones, and states what electrical and mechanical equipment is permitted in each zone as a result. It is the working document behind hazardous area classification.

What do the zone numbers mean?

Zones describe how often and for how long an explosive atmosphere is expected to be present, not how severe an explosion would be. Gas and vapour atmospheres use zones 0, 1 and 2 in descending order of persistence; dust atmospheres use zones 20, 21 and 22 on the same logic. A zone 0 or 20 area is expected to have the atmosphere present continuously or for long periods.

Who can carry out a zoning assessment?

A person competent in hazardous area classification, which is a distinct competence from general safety assessment. It requires understanding the release sources, the ventilation regime and the classification methodology well enough to justify a zone boundary that will be relied on for equipment selection, not just to tick a box that an assessment occurred.

Scope

When is an explosive atmosphere zoning record required?

Zoning is the classification instrument, and its boundary is with the substance-level and equipment-level records either side of it. Using it to do their job leaves gaps that surface only when equipment or a substance is checked in isolation.

Use this template when

  • A new area, process or piece of equipment could release a flammable dust, vapour or gas
  • An existing zoned area has changed in substance, throughput, ventilation or layout
  • Equipment is being specified or purchased for an area that may carry an explosive atmosphere
  • A dust or vapour source has been identified that was not previously assessed
  • The explosion protection document needs a current classification to reference

Do not use it for

  • Dust Hazard Assessment, which quantifies the combustibility and explosibility of a specific dust rather than classifying the areas it is handled in
  • Chemical Substitution Assessment, which is used when a flammable substance is being replaced rather than zoned in place
  • Restricted Substance Compliance Record, which tracks regulatory restriction on a substance, not the physical explosion risk of handling it
  • Risk Assessment, which is the general instrument and will not carry the classification methodology a zoning decision needs
  • Electrical inspection records, which verify installed equipment against its rating rather than establishing what rating the area requires

Compliance mapping

Which ISO 45001 cl.6.1.2 requirements does this satisfy?

Zoning sits inside a small family of instruments unusually specific for safety documentation: the methodology, the equipment categories and the marking requirements are all prescribed.

ClauseRequirementWhere it lands
ATEX 1999/92/EC art.4Classification of places where explosive atmospheres may occur into zonesIdentification
IEC 60079-10-1 / 60079-10-2Methodology for determining zone extent from release source, rate and ventilationIdentification
ATEX 2014/34/EUEquipment and protective systems intended for use in potentially explosive atmospheres carry a category matched to the zoneEquipment
OSHA 29 CFR 1910.307Electrical equipment and wiring in hazardous (classified) locations installed and marked to the location's classificationEquipment
DSEAR 2002Places classified into zones marked at their points of entryManagement
ATEX 1999/92/EC art.7 / Annex IIExplosion protection document setting out the classification, the measures taken and their adequacyOutcome
ISO 45001 cl.6.1.2Hazard identification proactive and ongoing, extended here to release sources and ignition sourcesHeader
ISO 45001 cl.8.1.2Elimination of hazards and reduction of risk, applied here to static control and earthing as engineering controlsEquipment

What it does not cover

  • Dust Hazard Assessment, which characterises the combustibility of the material itself and belongs alongside, not inside, the zoning record.
  • Chemical Substitution Assessment, which is the route for removing a flammable substance rather than classifying the area it is used in.
  • Restricted Substance Compliance Record, which addresses regulatory restriction on a substance and carries no explosion protection content.
  • A general Risk Assessment, which cannot substitute for the classification methodology a competent zoning assessment applies.
  • Hot work permit, which controls a single activity against zones that this record has already established, not the other way round.

Global

Explosive Atmosphere Zoning Record requirements by country

The duty to classify is close to universal wherever flammable dusts, vapours or gases are handled, but the three regimes differ in how prescriptive the equipment and marking rules are.

United States

OSHA 29 CFR 1910.307; NFPA 70 (NEC) Articles 500–506

Hazardous (classified) locations divided into classes and divisions, or zones under the NEC's alternative scheme, with equipment matched to each.

The class/division and zone systems coexist in US practice, and a record must state which one it uses rather than mixing terminology.

United Kingdom

DSEAR 2002, implementing the ATEX workplace directive

Places classified into zones, marked at entry points, with an explosion protection document required.

The explosion protection document is the enforceable output; a zoning record without one is an incomplete implementation of the duty.

European Union

ATEX 1999/92/EC (workplace); ATEX 2014/34/EU (equipment)

Two directives cover the same subject from opposite ends: the workplace directive requires classification, the equipment directive sets equipment categories.

A zone is meaningful only once matched against the equipment directive's category system, which is why the two are cited together.

How to complete it

How to complete an explosive atmosphere zoning record, step by step

The template prompts for a classification and a set of yes/no equipment checks. What makes the record defensible is the reasoning connecting the release source to the zone, and keeping equipment decisions downstream of that reasoning rather than ahead of it.

Classify before selecting equipment, never after

Equipment is frequently ordered, or already installed, before the zone extent is formally determined, on the assumption that whatever was specified last time will do again. Recording equipment suitability without a documented zone behind it inverts the logic the methodology depends on.

Treat the release source, not the room, as the unit of assessment

A single area can contain several release sources with different grades, and the zone extent follows each source rather than the room boundary. Classifying a room as one zone usually understates the extent around the actual source and overstates it everywhere else.

Give portable and vehicle-borne ignition sources an explicit rule

Fixed equipment gets checked once and stays checked. Phones, tools and trucks that move in and out of a zoned area cause the most incidents, because nothing in a static equipment register controls them without a written rule naming what is permitted to enter.

Write the explosion protection document as the output, not paperwork alongside it

The document is where the classification, the equipment measures and their adequacy are argued together. A zoning record with the boxes ticked and no document behind it has produced data without the reasoning that makes it defensible after an incident.

What auditors find

Most common explosive atmosphere zoning record findings

Zoning findings rarely concern whether a record exists. They concern whether the zone still describes the area, and whether the equipment in it still matches the zone.

FindingClauseWhat fixes it
Equipment installed or purchased before the zone extent was determined.ATEX 2014/34/EUHold equipment specification against a current classification, not a prior installation's assumption.
Zone not reassessed after a change to substance, throughput or ventilation.ATEX 1999/92/EC art.4Link the zoning record to management of change so a process change raises the review automatically.
Portable equipment or vehicles entering a zoned area without a written control.DSEAR 2002State which portable items and vehicles are permitted in each zone and how that is enforced at the boundary.
Zone boundaries not marked at points of entry.DSEAR 2002Install signage at every entry point to a classified zone, not only the obvious ones.
Explosion protection document absent or not updated alongside the classification.ATEX 1999/92/EC art.7Produce or update the document as part of closing the record, not as a separate exercise.
Static control and earthing not verified for equipment handling flammable powders or liquids.ISO 45001 cl.8.1.2Verify earthing and bonding continuity as part of the assessment, with a record of the check.

Case in point

Case in point: the zone that was correct when it was drawn

A dairy classified its milk powder handling area on installation, assigning zone 22 around the filling head and equipment rated accordingly. The classification was competently done and matched the original throughput.

Three years later the site added a second filling line beside the first, sharing the same room. Nobody revisited the zoning, because the project was run as a capacity upgrade by production engineering, and the zoning record belonged to safety. The new line's release source extended the zone 22 boundary well past where the original equipment specification assumed it stopped, and standard-rated equipment was installed inside the extended boundary unclassified.

The template

The template, field by field

The form exactly as it installs. Every field, option, score and conditional rule is editable, and the links to other templates come with it.

47fields
6 sections
Reference
ENV-050
Archetype
Assessment
Record ID
EAZ-2026-000
Scoring
Zones compliant
Direction
High is good
Singleton
Yes
Basis
ISO 45001 cl.6.1.2
Links
Links Combustible dust, Electrical
Tags
Chemicals, Explosive
Sections
6
Fields
47
Follow up fields
3
Repeating sections
0
Links out
5
Field typesOwn ID, generated on saveCase thread and parentPick list from a registryLinked to another templateFollow up, dashed outlineScored

Header

12 fields
Text

Assessment ID*

Generated on save

Auto sequence. Format EAZ-2026-000.

The record's own ID. Other templates point at this value.

Single Choice

Status*

Scored

Drives who this goes to next.

  • Planned2 pts
  • In progress2 pts
  • Complete3 pts
  • Deferred0 pts
  • Open0 pts
  • Closed3 pts
  • Overdue0 pts
Date & Time

Date and Time*

Users

Completed By*

Pick List

Site*

From FDN-001 Site NameFilter: Status is Active
Text

Site ID*

Linked

Format SITE-000.

Links to FDN-001 Site ID

Single Choice

Area

Optional

The area within the site.

Cutting roomBoning hallPackingChill storeFreezerPasteurisingFillingCulture roomDespatchYardWorkshopPlant roomOffices
Location

Exact Location

Optional

Drop a pin for anything hard to find.

Text

Area Or Equipment*

Single Choice

Atmosphere Type*

DustVapourGasMixed
Single Choice

Assessor Competent*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Info

Flour, Sugar And Cleaning Solvents All Create Zones

Sites assume explosive atmospheres are a chemical plant problem. A flour silo, a sugar handling bay and a solvent store all create zones that dictate what equipment may be used.

Identification

6 fields
Single Choice

Flammable Materials Identified*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Release Sources Identified*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Frequency And Duration Of Release Assessed*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Ventilation Effectiveness Assessed*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Zone Classification Assigned*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Zone Extent Determined*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts

Equipment

6 fields
Single Choice

Equipment Category Suitable For Zone*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Equipment Marked And Documented*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Portable Equipment Controlled*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Vehicles Excluded Or Suitable*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Static Control Measures In Place*

Scored
  • Yes2 pts
  • No0 pts
  • N/Aexcluded from denominator
Single Choice

Earthing And Bonding Verified*

Scored
  • Yes3 pts
  • No0 pts

Management

6 fields
Single Choice

Zones Marked On Site Plan*

Scored
  • Yes2 pts
  • No0 pts
  • N/Aexcluded from denominator
Single Choice

Signage At Zone Boundaries*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Hot Work Prohibited Or Controlled*

Scored
  • Prohibited4 pts
  • Permit controlled3 pts
  • Uncontrolled0 pts
Single Choice

Workers Trained On Zones*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Contractors Briefed On Zones*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Documentation Available And Current*

Scored
  • Yes2 pts
  • No0 pts
  • N/Aexcluded from denominator

Related records

1 field
Text

Restricted Substance ID

OptionalLinked

Substances relevant to the zoning.

Links to ENV-049 Record ID

Outcome

16 fields
Single Choice

Classification Complete*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Numeric Answer

Non Compliant Equipment Items*

Scored
Single Choice

Immediate Risk*

Scored
  • No3 pts
  • Yes0 pts
Single Choice

Explosion Protection Document Updated*

Scored
  • Yes3 pts
  • Not required3 pts
  • No0 pts
Text

Dust Assessment ID

OptionalLinked

Links to SAF-175 Assessment ID

Date & Time

Next Review Due*

Pick List

Risk Assessment

OptionalFrom FDN-012 Risk Title
Text

Risk ID

OptionalLinked

Format RSK-2026-00000.

Links to FDN-012 Risk ID

Single Choice

Action Required*

Scored

Raise the action record, then enter its reference here.

  • No2 pts
  • Yes0 pts
Single Choice

Priority

OptionalScoredShows if Action Required equals Yes
  • High0 pts
  • Medium1 pt
  • Low3 pts
Text

CAPA ID

OptionalLinkedShows if Action Required equals Yes

Format CAPA-2026-00000.

Links to FDN-014 CAPA ID

Users

Action Owner

OptionalShows if Action Required equals Yes
Users

Assessor*

Signature

Signature*

Users

Engineering Manager*

Signature

Second Signature*

ENV-050 · record IDs look like EAZ-2026-000 · Links Combustible dust, Electrical

Open in Knowella

Run it with agents

From a document you fill in to a programme that runs itself

The classification is easy to get right once. What fails is noticing the process change that should trigger a new one, and keeping the equipment register in step with the zone.

KnowEnviro

Holds the zoning record against the site's substance and equipment registers, and flags equipment that no longer matches its zone.

KnowMaintain

Connects equipment category requirements to the maintenance schedule, so a zoned item's rating is verified on the same cycle as its condition.

KnowSafe

Links hot work permits and contractor briefings to the current zone map, rather than a version last printed at the workface.

Ella
Ella

Watches management of change and layout records for events that should trigger a re-zoning, and raises the review before the register drifts out of step.

This template lives in KnowEnviro — environment and energy. Aspects, permits, waste, emissions, spills and sustainability reporting.

Meet KnowEnviro→

Glossary

Explosive Atmosphere Zoning Record definitions and key terms

Zone
A classification of an area by how often and for how long an explosive atmosphere is expected to be present, using 0/1/2 for gas and vapour and 20/21/22 for dust.
Release source
A point or surface from which a flammable dust, vapour or gas can escape into the atmosphere, and the feature that determines a zone's extent.
Equipment category
The rating under the equipment directive that states which zone a piece of electrical or mechanical equipment is permitted to operate in.
Explosion protection document
The record setting out the classification, the measures taken to control ignition sources, and the adequacy of those measures for the zones identified.
Zone extent
The distance a classified atmosphere is judged to reach from its release source, determined by release rate, grade and ventilation rather than by room boundary.

FAQ

Frequently asked questions about explosive atmosphere zoning record

Do ordinary food or logistics sites need zoning records?+

Yes, wherever a combustible dust, flammable solvent or fuel vapour is handled in quantity. Flour, sugar, milk powder and cleaning solvent all generate atmospheres capable of being classified, and assuming zoning is a chemical-plant concern is the single most common reason it gets skipped.

Can one person both classify the zone and select the equipment?+

Yes, but the two decisions must be recorded as sequential rather than combined, because equipment selected without a documented zone in front of it cannot later be shown to have followed the classification rather than preceded it.

What triggers a re-zoning rather than a routine review?+

Any change to the substance handled, the throughput, the layout or the ventilation regime. A stated review interval is a backstop for change nobody flagged, because a zone correct on the review date can be wrong within weeks of a process change.

Does portable equipment need to be zoned separately from fixed equipment?+

Yes. Fixed equipment is installed once against a known zone and checked periodically. Portable tools, phones and vehicles move between zoned and unclassified areas and need an explicit rule, because a static equipment register does not control something that moves.

Is the explosion protection document the same thing as the zoning record?+

No. The zoning record establishes the classification; the document is the wider argument that classification, ignition-source controls and equipment measures together are adequate. A site needs both, and the document should reference the current record rather than restate it.

How is zone extent actually calculated?+

From the release source's grade, rate and the ventilation diluting it, following a methodology such as IEC 60079-10. It is not a fixed distance applied uniformly, and assigning the same extent to every source regardless of its release characteristics has not applied the methodology.

Keep going

Related templates and programmes

Siddarth Singh

Written and reviewed by

Siddarth Singh

Founder & Chief Executive Officer, Knowella

Certified Safety Professional and industrial and systems engineer with more than a decade inside food supply chain, freight and manufacturing operations. This page was written against the current text of the standards it cites, not against secondary summaries of them.

  • Certified Safety Professional (CSP), Board of Certified Safety Professionals
  • MBA, University of Chicago Booth School of Business
  • MS and BS, The Ohio State University, Industrial and Systems Engineering
  • Six Sigma Black Belt
Verify with BCSP →

Sources and last review. Reviewed 16 August 2026 against:

  • ATEX 1999/92/EC — minimum requirements for improving the safety and health of workers potentially at risk from explosive atmospheres
  • ATEX 2014/34/EU — equipment and protective systems intended for use in potentially explosive atmospheres
  • DSEAR 2002 — Dangerous Substances and Explosive Atmospheres Regulations (UK)
  • IEC 60079-10-1 / 60079-10-2 — classification of areas: explosive gas atmospheres / combustible dust atmospheres
  • OSHA 29 CFR 1910.307 — hazardous (classified) locations

This page is general guidance, not legal advice. Confirm requirements with your jurisdiction’s regulator.

Start in Minutes, Not Weeks

Launch a Ready-Made Template and Customize It Your Way

Every template is fully editable. Adjust fields, workflows, and branding to match your processes, then deploy to your team instantly.