What this is
What is an eyewash and shower inspection?
What is an eyewash and shower inspection?
It is the periodic check that an emergency eyewash station or safety shower will function when needed: adequate flow for the full required duration, tepid clear water, and a path a person can reach within ten seconds without obstruction. It is an activation test of the equipment, not a review of the chemical hazard itself.
Who should carry out the inspection?
ANSI Z358.1 expects the weekly activation to be done by whoever is assigned the area, without special qualification, because it is a flush and a visual check. An annual verification against the full flow, temperature and volume requirements is more technical and often falls to a maintenance or safety function.
Why is the ten-second rule central to this template?
ANSI Z358.1 sets ten seconds of unobstructed travel as the limit before injury from a splash worsens materially. A unit that passes every other check but sits behind a pallet or a longer route than that fails the standard regardless of flow rate, which is why access and travel time are scored alongside the mechanical checks.
Scope
When is an eyewash and shower inspection required?
This inspection is scoped to the eyewash or shower unit itself. It does not assess the chemical hazard the unit exists to respond to, and it should not be the record of a substitute for that assessment.
Use this template when
- A weekly activation is due on a plumbed or self-contained eyewash station, safety shower, combination unit or portable eyewash
- A unit has been newly installed or relocated and needs its first check against travel time and access
- An area around an existing unit has changed, new equipment, racking or a locked door, and the access and travel time need re-checking
- A unit has previously failed and a follow-up check is needed to confirm the fix held
- A complaint or near miss has raised doubt about whether a specific unit actually works
Do not use it for
- Chemical or COSHH risk assessment, which decides what corrosive hazard requires a unit nearby, and which this inspection does not evaluate
- General Workplace Inspection, a broad walkthrough that will not catch a unit whose flow rate or reach has drifted out of spec
- First Aid Kit Inspection, which covers stocked supplies rather than fixed emergency equipment
- Water hygiene or Legionella monitoring, which addresses standing-water risk in low-flow plumbing, a distinct programme from the weekly flush
- New equipment commissioning, where flow rate and travel distance are verified once at installation, not checked weekly
Compliance mapping
Which ANSI Z358.1 requirements does this satisfy?
ANSI Z358.1 is a consensus standard, not a federal regulation, but it is incorporated by reference through the general duty to provide adequate emergency equipment where corrosive materials are handled.
| Clause | Requirement | Where it lands |
|---|---|---|
| ANSI Z358.1 sec.4 | Plumbed and self-contained eyewash equipment activated weekly to verify flow and flush sediment | Units |
| ANSI Z358.1 sec.7 | Emergency shower equipment activated weekly to verify adequate, uninterrupted flow | Units |
| ANSI Z358.1 | Unit reachable within ten seconds on an unobstructed path from the hazard | Units |
| ANSI Z358.1 | Flushing fluid delivered tepid, in the range that supports the full flush duration without inducing hypothermia | Units |
| ANSI Z358.1 | Equipment identified by highly visible signage from the approach | Units |
| ANSI Z358.1 | Protective caps or covers maintained to keep the nozzle free of contamination between uses | Units |
| OSHA 1910.151(c) | Suitable facilities for quick drenching or flushing provided where corrosive materials may injure the eyes or body | Units |
What it does not cover
- COSHH or chemical risk assessment, which decides whether the corrosive exposure itself is controlled, rather than confirming the response equipment works.
- First Aid Kit Inspection, the separate check of stocked supplies rather than fixed emergency equipment.
- Water hygiene or Legionella management, which addresses standing water risk in low-flow plumbing and needs its own programme beyond the weekly flush.
- New equipment commissioning record, which verifies flow rate and reach against the full ANSI specification at installation.
- General Workplace Inspection, a broad walkthrough that will not reliably catch a unit whose access or flow has drifted.
Global
Eyewash and Shower Inspection requirements by country
The duty to provide the equipment is close to universal where corrosive materials are handled. What differs is whether a named consensus standard is written into law or left as the practical benchmark.
OSHA 1910.151(c); ANSI Z358.1 as the consensus benchmark
OSHA requires suitable facilities without naming a schedule; ANSI Z358.1 supplies the weekly and annual regime employers actually follow.
An employer cited under the general duty clause is judged against the ANSI schedule even though OSHA's own text does not specify one.
COSHH Regulations 2002, regulation 8; Workplace (Health, Safety and Welfare) Regulations 1992
Regulation 8 requires control measures, including emergency equipment, to be maintained in an efficient state and kept in good repair.
A unit found not working at inspection is a maintenance-duty breach independently of whether the site follows ANSI at all.
ANSI Z358.1, applied as the de facto global benchmark
No ISO standard governs eyewash and shower equipment specifically, so multinational operators typically apply ANSI Z358.1 regardless of local regulatory silence.
A site outside the US is rarely legally required to meet ANSI, but auditors and insurers usually expect it anyway.
How to complete it
How to complete an eyewash and shower inspection, step by step
The template prompts a pass or fail on each mechanical check. The judgement calls that decide whether the record actually protects someone sit around those checks, not inside them.
A weekly activation confirms the unit flows and clears sediment; it does not confirm the flow rate and duration meet the ANSI figures for that unit type. Recording a weekly pass as if it were a full verification overstates what was checked.
The path to the unit is as likely to have changed as the unit itself, and more likely to change without anyone deciding it should. Every inspection has to re-check the route, because a layout change is invisible to a checklist scoped to the equipment.
Few sites fit a thermometer at the point of use, so the inspector judges by hand whether the water is neither scalding nor cold enough to add hypothermia to a chemical injury. That is a known limitation, and it should be treated as one rather than passed over silently.
The catalogue treats a water or access failure as urgent, but the template does not itself take the process nearby offline. Completing the record well means deciding, at the point of failure, whether adjacent work should stop until the unit is restored.
What auditors find
Most common eyewash and shower inspection findings
Findings on this template rarely concern whether the inspection happened. They concern whether a mechanically sound unit was actually reachable and usable when it mattered.
| Finding | Clause | What fixes it |
|---|---|---|
| Weekly activation not performed; flow only checked when a fault is reported. | ANSI Z358.1 sec.4 / sec.7 | Schedule the weekly activation and require the record before the next one is due. |
| Travel time exceeds ten seconds because racking or stored material was added near the unit. | ANSI Z358.1 | Re-site the unit or clear the obstruction; re-walk the route at every inspection. |
| Water is not tepid; it runs cold in winter or hot in summer depending on supply. | ANSI Z358.1 | Fit a tempering valve sized for the unit's flow rate rather than relying on ambient supply. |
| Protective caps missing, cracked, or fouled with sediment, defeating their purpose. | ANSI Z358.1 | Replace caps immediately and record the fault as a fail, since the nozzle is not sanitary as found. |
| Signage missing or not visible from the direction a person would approach. | ANSI Z358.1 | Reposition or add signage visible along the real approach path, not only front-on. |
| Unit recorded as failed but the adjacent chemical process was not restricted, no work order raised. | ANSI Z358.1 / site policy | Make the work order mandatory on any fail and record whether nearby work was stopped. |
Case in point
Case in point: the unit that always passed on paper
A finishing line kept a portable eyewash station near its solvent bench. The weekly inspection recorded a pass for eighteen straight months: the flush ran, the caps were on, signage was visible. Six months earlier a second workstation had been installed in front of the unit to handle overflow, narrowing the approach and adding a step around the new bench to reach it.
When a splash occurred, the operator's actual route took closer to fifteen seconds because of the new bench, not the ten the standard assumes. The inspection had kept checking the unit and never re-walked the path, because nothing on the form asked whether anything had changed around it.
The template
The template, field by field
The form exactly as it installs. Every field, option, score and conditional rule is editable, and the links to other templates come with it.
3 sections
- Reference
- SAF-031
- Archetype
- Inspection
- Record ID
- INSP-2026-000
- Scoring
- Pass or fail
- Direction
- High is good
- Singleton
- No
- Basis
- ANSI Z358.1
- Links
- Links Asset; feeds work order
- Tags
- Inspection, Emergency
- Sections
- 3
- Fields
- 38
- Follow up fields
- 5
- Repeating sections
- 1
- Links out
- 4
Header
7 fieldsInspection ID*
Auto sequence. Format INSP-2026-00000.
The record's own ID. Other templates point at this value.
Status*
Drives who this goes to next.
- Planned2 pts
- In progress2 pts
- Complete3 pts
- Deferred0 pts
- Open0 pts
- Closed3 pts
- Overdue0 pts
Date and Time*
Inspection Type*
Scheduled, unscheduled, follow up or post incident.
Site*
Site ID*
Format SITE-000.
Links to FDN-001 Site ID
Two Things Must Pass
Water flow and clear access. Either failing is urgent, because these are used in the first ten seconds of a chemical splash.
Units
Repeats16 fieldsUnit*
Asset ID*
Format AST-0000.
Links to FDN-002 Asset ID
Unit Type*
Location*
Nearest Chemical Hazard
Access Clear And Unobstructed*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Signage Visible*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Within 10 Seconds Travel*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Flushed For Full Duration*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Flow Adequate And Steady*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Water Clear And Tepid*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Caps Or Covers Intact*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
No Leaks Or Damage*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Result*
- Pass3 pts
- Pass with conditions2 pts
- Fail0 pts
Work Order ID
Links to MNT-002 Work Order ID
Photo
Result
15 fieldsItems Assessed*
Excludes anything marked N/A.
Items Failed*
Score Percent*
Calculated on submission. High is good. N/A items leave the denominator.
Result Band*
- Pass3 pts
- Caution1 pt
- Fail0 pts
Completeness Percent*
How much of the template was actually answered. A high score on a half completed form is not a high score.
Findings Raised
Highest Severity Found
- Observation3 pts
- Minor2 pts
- Major0 pts
Action Required*
Raise the action record, then enter its reference here.
- No2 pts
- Yes0 pts
Priority
- High0 pts
- Medium1 pt
- Low3 pts
CAPA ID
Format CAPA-2026-00000.
Links to FDN-014 CAPA ID
Action Owner
Next Inspection Due
Notes
Inspected By*
Signature*
SAF-031 · record IDs look like INSP-2026-000 · Links Asset; feeds work order
Open in KnowellaRun it with agents
From a document you fill in to a programme that runs itself
The unit itself is simple to check. What slips is noticing that the area around it changed since the last pass, and that a fail actually reaches the people working nearby.
Holds the eyewash and shower register against the asset list, flags units due their weekly activation, and keeps the fail-to-work-order link intact.

Watches layout and equipment changes logged elsewhere on site and raises a travel-time re-check for any unit whose surroundings have moved, rather than waiting for the next scheduled round.
Takes the work order raised on a fail result and tracks the repair to completion before the unit is returned to service.
This template lives in KnowSafe — safety and compliance. Incidents, hazards, permits, inspections and the critical controls behind them.
Meet KnowSafe→Glossary
Eyewash and Shower Inspection definitions and key terms
- Tepid water
- Water delivered in a temperature range that supports the full flush duration without itself causing injury from heat or cold, judged by feel where no thermometer is fitted.
- Weekly activation
- The routine flush of a plumbed unit that clears sediment and confirms flow, distinct from the annual verification against the full ANSI flow and volume specification.
- Ten-second rule
- The ANSI Z358.1 benchmark that a person exposed to a splash should be able to reach the unit within ten seconds on an unobstructed path.
- Combination unit
- A single installation providing both an eyewash or eyewash/face wash and a full-body shower at one location.
- Plumbed versus self-contained
- A plumbed unit is connected to a continuous water supply and flushed weekly; a self-contained unit holds its own flushing fluid and is checked and replaced on the manufacturer's schedule.
FAQ
Frequently asked questions about eyewash and shower inspection
How often does an eyewash or shower need to be checked?+
Weekly for the activation flush that confirms flow and clears sediment, and at least annually for a full check against ANSI Z358.1's flow rate, volume and duration figures. The weekly check does not substitute for the annual one; it catches a different class of fault.
What temperature counts as tepid?+
ANSI Z358.1 specifies a range intended to support fifteen minutes of flushing without the water itself causing harm. Few sites measure it directly at the unit, so most inspections judge it by feel, a known limitation rather than a compliant measurement.
Does a portable eyewash satisfy the requirement as well as a plumbed unit?+
It can, where a plumbed supply is not available, but it carries its own maintenance burden: the fluid has an expiry and must be replaced on schedule, and its flow duration is limited by the reservoir it carries.
What should happen when a unit fails inspection?+
The fault should be treated as urgent rather than queued as routine maintenance, and the process the unit protects should be restricted until it is restored. Recording a fail and continuing as before defeats the purpose of the check.
Does the ten-second rule apply to every hazard nearby?+
It applies to any location where a person could be splashed, which is why a layout change near the unit, not just a change to the unit, should trigger a re-check of travel time.
Who is qualified to run the weekly activation?+
Anyone assigned the area; it is a flush and a visual check rather than a technical exercise. The annual full verification is more often assigned to a maintenance or safety function.
Keep going
Related templates and programmes
Industries this is written for
Programmes this belongs to
Used together in Workplace Inspection
Audit Finding Record
Records a single audit finding with its evidence, clause reference and classification
Finding
Records a single deficiency picked up during an audit, inspection or check
General Workplace Inspection
A broad walk through of an area covering the common hazards
Housekeeping Inspection
Checks that walkways, work areas and storage are clear, clean and in order
PPE Compliance Inspection
Checks that the right protective equipment is available, in good condition and being worn
Electrical Safety Inspection
Checks panels, cords, outlets and portable equipment for damage and safe access
More in Safety Inspections
General Workplace Inspection
A broad walk through of an area covering the common hazards
Housekeeping Inspection
Checks that walkways, work areas and storage are clear, clean and in order
PPE Compliance Inspection
Checks that the right protective equipment is available, in good condition and being worn
Electrical Safety Inspection
Checks panels, cords, outlets and portable equipment for damage and safe access
Ladder Inspection
Checks each ladder for damage, missing feet, loose rungs and correct labelling
Fall Arrest Equipment Inspection
Checks harnesses, lanyards and connectors for wear, damage and expiry

Written and reviewed by
Siddarth Singh
Founder & Chief Executive Officer, Knowella
Certified Safety Professional and industrial and systems engineer with more than a decade inside food supply chain, freight and manufacturing operations. This page was written against the current text of the standards it cites, not against secondary summaries of them.
- Certified Safety Professional (CSP), Board of Certified Safety Professionals
- MBA, University of Chicago Booth School of Business
- MS and BS, The Ohio State University, Industrial and Systems Engineering
- Six Sigma Black Belt
Sources and last review. Reviewed 16 August 2026 against:
- ANSI Z358.1 — Emergency Eyewash and Shower Equipment
- OSHA 1910.151(c) — Medical services and first aid, quick drenching and flushing
- COSHH Regulations 2002, regulation 8 (GB) — maintenance of control measures
- Workplace (Health, Safety and Welfare) Regulations 1992 (GB)
This page is general guidance, not legal advice. Confirm requirements with your jurisdiction’s regulator.