Glove Selection and Suitability Record

A glove selection and suitability record documents why a particular glove was chosen for a task, weighing breakthrough time against dexterity, skin tolerance and fit. Its recurring failure is treating chemical resistance as the whole answer: a glove rated correctly against a data sheet gets specified, workers find it too thick or hot to work in, and it either comes off mid-task or stays on long enough to cause the skin condition it was meant to prevent.

KnowHealthRecordHLT-04745 fields across 5 sectionsFull researchSee the form

Reviewed by Siddarth SinghCSPLast reviewed 16 August 2026

Basis
ISO 45001 cl.8.1
Workspace
KnowHealth
Form type
Record
Completed by
Safety with the users, not safety alone
Reviewed
On chemical or task change, not on a fixed calendar

The short version

  • A glove rated correctly against the chemical hazard can still be the wrong glove, because dexterity, heat and fit determine whether it stays on and is worn correctly for the whole task.
  • Breakthrough time is a duration match against the task, not a lookup that ends the decision. A short task against a long breakthrough time has margin; a long task against a short one does not.
  • The wrong glove causes dermatitis as readily as no glove, through occlusion and sweat, so chemical resistance and skin tolerance need weighing together rather than chemical resistance winning by default.
  • The selection is provisional until the trial and the skin check programme confirm it in use; a specification never tried on the people who wear it is a guess dressed as a decision.

What this is

What is a glove selection and suitability record?

What is a glove selection and suitability record?

It is the record that ties a specified glove to a specific task, documenting the chemical and mechanical protection it needs, the breakthrough time against the substances contacted, and whether the glove is wearable for the task's duration and nature. It exists because a glove can be correctly rated and still be the wrong choice.

What is breakthrough time and why does it matter here?

The measured interval between a chemical first contacting a glove's outside and detectable permeation to the inside, under standard test conditions. It matters because a glove is only adequate if breakthrough time exceeds how long the worker actually wears it for the task; a short task against a long breakthrough time has margin, a long task against a short one does not.

Who should be involved in confirming a glove is suitable?

Safety, who knows the hazard and the rating, and the workers who wear it, who know whether it can be worked in. A selection made from a data sheet alone, without a trial, routinely misses dexterity and heat problems that lead workers to remove the glove or tolerate it badly.

Scope

When is a glove selection and suitability record required?

This record confirms one glove for one task; it does not assess the chemical hazard or the worker's skin condition in its own right. Using it as a substitute produces a suitability decision with nothing underneath it.

Use this template when

  • A task involving chemical, mechanical or thermal hand hazards is being specified for the first time
  • A new chemical changes the breakthrough time requirement for an existing glove
  • A dermatitis case or worker complaint suggests the current glove is not suitable
  • A periodic review of the glove specification is due
  • A worker requests a change because the current glove cannot be worked in

Do not use it for

  • Dermatitis Risk Assessment, which assesses wet work, chemical contact and glove use across a role, rather than one glove for one task.
  • Skin Inspection Record, which records a structured look at hands and forearms for early dermatitis signs, not the glove decision preceding it.
  • A chemical exposure assessment, which characterises the substance and route, not the glove chosen against it.
  • A PPE specification or equipment register, which holds sizing, stock and issue, not the suitability reasoning.
  • A training record, which evidences that users can don, doff and inspect the glove, not that it is the right glove.

Compliance mapping

Which ISO 45001 cl.8.1 requirements does this satisfy?

Glove standards are unusually specific: the ratings are numeric, published and testable, which makes the failure mode less about ambiguity and more about whether the rating was matched to the right thing.

ClauseRequirementWhere it lands
ISO 45001 cl.8.1.2Personal protective equipment specified only once elimination, substitution, engineering and administrative controls have been consideredHeader
EN 374-1Classification of chemical protective gloves by breakthrough time against a defined list of test chemicalsProtection
EN 388Classification of gloves against mechanical risks: abrasion, cut, tear and puncture resistanceProtection
EN 420General requirements for gloves including ergonomics, dexterity, sizing and comfort under intended useWearability
EU Regulation 1935/2004Materials intended for food contact must not transfer their constituents to food in quantities that endanger healthFood and use
ISO 45001 cl.9.1.1Monitoring and measurement of the effectiveness of controls, including whether a specified glove continues to perform in useOutcome

What it does not cover

  • Dermatitis Risk Assessment, which assesses wet work, chemical contact and glove use across a role for dermatitis risk.
  • Skin Inspection Record, which records a structured examination of hands and forearms for early dermatitis signs.
  • A chemical exposure assessment or register, which characterises the substance itself rather than the glove chosen against it.
  • A PPE specification or equipment record, which holds sizing, stock and issue, not the suitability decision.
  • A training record, which evidences competence in donning, doffing and inspecting the glove, not that the glove is correct.

Global

Glove Selection and Suitability Record requirements by country

Glove selection duties sit inside the general PPE obligation almost everywhere, with the European EN ratings serving as a de facto technical benchmark even outside Europe.

United States

OSHA 29 CFR 1910.138, Hand Protection

Employers must select hand protection based on an evaluation of performance characteristics relative to the task, conditions and duration of use.

OSHA does not mandate EN ratings, but citing them as the selection basis provides the evidence the standard requires; habit or brand preference does not.

United Kingdom

Personal Protective Equipment at Work Regulations 1992 (as amended)

PPE must be suitable, including being appropriate to the risk, the conditions, and the wearer's ergonomic requirements and health.

HSE expects ergonomic and dexterity considerations evidenced, not just the chemical or mechanical rating, since suitability is defined to include both.

International

ISO 45001; EN 374 and EN 388

The management system requires monitoring control effectiveness; the EN standards give the objective ratings a selection is checked against.

Certification audits check the record cites an actual rated performance against the actual hazard, not a general glove description.

How to complete it

How to complete a glove selection and suitability record, step by step

The rated fields are the easy part, because the numbers exist on a data sheet. What decides whether the glove actually works is the judgement applied around those numbers.

Treat breakthrough time as a duration match, not a chart lookup

The rating only means something once set against how long the glove is actually worn, including incidental contact before or after the main step. A glove reused across a shift longer than its breakthrough time stops protecting once that time is exceeded.

Weigh skin risk alongside chemical risk, not after it

A glove chosen purely for chemical resistance can cause the dermatitis it was meant to prevent, through occlusion and sweat trapped against the skin for hours at a time. The most resistant glove is not automatically the safer choice once skin tolerance is considered.

Trial with the actual users before finalising

Dexterity, grip when wet and heat tolerance cannot be judged from a specification sheet, and workers will route around a glove that fails on any of them, usually by removing it. A trial that surfaces the problem before finalising is cheaper than a dermatitis case that surfaces it afterwards.

Treat the specification as provisional until the skin check programme confirms it

A suitability decision made on paper is a hypothesis about how the glove performs in use. Linking it to the skin check programme closes that loop, so a developing reaction gets connected back to the glove that may be causing it.

What auditors find

Most common glove selection and suitability record findings

Glove selection findings look identical on paper and diverge badly in practice. The rating was correct; the decision around it was not.

FindingClauseWhat fixes it
Glove specified without checking breakthrough time against actual task duration.EN 374-1Record task duration alongside breakthrough time and confirm the margin before finalising.
Cut or mechanical resistance not verified where a mechanical hazard sits alongside the chemical one.EN 388Assess mechanical and chemical hazards together, not whichever was noticed first.
Glove finalised without user consultation or a trial in the actual task conditions.PPE at Work Regulations 1992, reg.4Require a documented trial with the workers who perform the task before confirming.
Food contact approval not confirmed for gloves used in a food handling task.EU Regulation 1935/2004Check food contact approval whenever chemicals contacted indicate raw food material handling.
Glove chosen for chemical resistance alone, with skin tolerance and occlusion not considered.ISO 45001 cl.8.1.2Record skin tolerance as a distinct judgement, not assumed from a good chemical rating.
Specification not linked to the skin check programme, so a developing reaction is not connected to the glove.ISO 45001 cl.9.1.1Link every specification to the skin check programme so a finding traces back to the glove.

Case in point

Case in point: the glove that passed on paper and failed on the line

A cleaning task using chlorine-based disinfectant had its glove specified from the safety data sheet's chemical resistance chart alone: nitrile, rated for the substance, breakthrough time comfortably longer than the task. The record marked breakthrough time and degradation as adequate, but user consultation and trial were both left as no, since the glove was already in stock and the specification was treated as a formality.

On the line, workers found the thickness too stiff to grip small connector fittings in the same task, and started removing the gloves for that part of the job while leaving them on for the rest. Within a season, several developed contact dermatitis, some from unprotected contact during the ungloved portions and some from prolonged sweat trapped inside a glove correctly rated but too thick to wear continuously. The chemical rating had been right all along; the decision around it had never been tested against the people doing the work.

The template

The template, field by field

The form exactly as it installs. Every field, option, score and conditional rule is editable, and the links to other templates come with it.

45fields
5 sections
Reference
HLT-047
Archetype
Record
Record ID
GSR-2026-000
Scoring
Suitability confirmed
Direction
High is good
Singleton
No
Basis
ISO 45001 cl.8.1
Links
Links Chemical register, PPE
Tags
Skin health, PPE
Sections
5
Fields
45
Follow up fields
3
Repeating sections
0
Links out
3
Field typesOwn ID, generated on saveCase thread and parentPick list from a registryLinked to another templateFollow up, dashed outlineScored

Header

13 fields
Text

Record ID*

Generated on save

Auto sequence. Format GSR-2026-000.

The record's own ID. Other templates point at this value.

Single Choice

Status*

Scored

Drives who this goes to next.

  • Planned2 pts
  • In progress2 pts
  • Complete3 pts
  • Deferred0 pts
  • Open0 pts
  • Closed3 pts
  • Overdue0 pts
Date & Time

Date and Time*

Users

Completed By*

Pick List

Site*

From FDN-001 Site NameFilter: Status is Active
Text

Site ID*

Linked

Format SITE-000.

Links to FDN-001 Site ID

Text

Task*

Single Choice

Glove Type Specified*

Nitrile disposableNitrile reusableLatexPVCChain mailCut resistantThermal
Single Choice

Selection Trigger*

New chemicalNew taskDermatitis casePeriodic reviewWorker request
Single Choice

Chemicals Contacted*

Caustic cleanersAcid cleanersChlorine disinfectantsPeracetic acidSolventsRaw food materialsNone
Text

Substance ID

OptionalLinked

Links to FDN-006 Substance ID

Single Choice

Data Sheet Consulted*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Info

The Wrong Glove Causes Dermatitis Too

A glove chosen only for chemical resistance can cause the very condition it was meant to prevent, through occlusion and sweat. Both hazards need considering together.

Protection

6 fields
Single Choice

Breakthrough Time Adequate For The Task*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Degradation Rating Acceptable*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Permeation Data Available*

Scored
  • Yes2 pts
  • No0 pts
  • N/Aexcluded from denominator
Single Choice

Cut Resistance Where Needed*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Thermal Protection Where Needed*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Length Adequate For The Task*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts

Wearability

6 fields
Single Choice

Dexterity Adequate*

Scored
  • Yes3 pts
  • Marginal1 pt
  • No0 pts
Single Choice

Grip Adequate When Wet*

Scored
  • Yes3 pts
  • Marginal1 pt
  • No0 pts
Single Choice

Sizes Available For All Workers*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Cotton Liner Provided Where Needed*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Change Frequency Defined*

Scored
  • Yes3 pts
  • No0 pts
Single Choice

Skin Tolerance Considered*

Scored
  • Yes3 pts
  • No0 pts

Food and use

6 fields
Single Choice

Food Contact Approved Where Required*

Scored
  • Yes2 pts
  • No0 pts
  • N/Aexcluded from denominator
Single Choice

Detectable Or Coloured For Visibility*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Single Use Or Reusable Defined*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Storage And Disposal Defined*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Users Consulted*

Scored
  • Yes3 pts
  • Some1 pt
  • No0 pts
Single Choice

Trial Carried Out*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts

Outcome

14 fields
Single Choice

Suitability Confirmed*

Scored
  • Yes2 pts
  • No0 pts
  • N/Aexcluded from denominator
Text

Conditions Of Use

Optional
Single Choice

Users Trained*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Added To PPE Specification*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Skin Check Programme Linked*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Date & Time

Review Date*

Single Choice

Action Required*

Scored

Raise the action record, then enter its reference here.

  • No2 pts
  • Yes0 pts
Single Choice

Priority

OptionalScoredShows if Action Required equals Yes
  • High0 pts
  • Medium1 pt
  • Low3 pts
Text

CAPA ID

OptionalLinkedShows if Action Required equals Yes

Format CAPA-2026-00000.

Links to FDN-014 CAPA ID

Users

Action Owner

OptionalShows if Action Required equals Yes
Users

Safety Lead*

Signature

Signature*

Users

Occupational Health*

Signature

Second Signature*

HLT-047 · record IDs look like GSR-2026-000 · Links Chemical register, PPE

Open in Knowella

Run it with agents

From a document you fill in to a programme that runs itself

The specification itself is straightforward to complete. What slips is the link between the glove in use, the chemical it resists, and the skin condition it is meant to prevent.

KnowHealth

Holds the glove specification against the skin check programme, connecting a developing reaction back to the glove rather than logging it as unrelated.

KnowSafe

Links the specification to the chemical register and the task it protects, flagging specifications not revisited after a substance change.

KnowQuality

Checks food contact approval where a task involves raw food materials, and keeps that evidence alongside the food safety record.

Ella
Ella

Watches dermatitis and skin check findings for a pattern pointing at a specific glove, and raises the specification for review.

This template lives in KnowHealth — employee wellbeing. Exposure monitoring, health surveillance, case management and return to work.

Meet KnowHealth→

Glossary

Glove Selection and Suitability Record definitions and key terms

Breakthrough time
The measured interval between a chemical first contacting a glove's outer surface and detectable permeation to the inside, under standard test conditions.
Permeation
The process by which a chemical passes through a glove material at the molecular level, distinct from physical damage, and the basis for breakthrough time testing.
Degradation
A physical change in a glove material from chemical contact, such as swelling, hardening or cracking, which can compromise protection before breakthrough time is reached.
Occlusion
The trapping of moisture, heat and sweat against the skin under an impermeable glove, a recognised cause of irritant contact dermatitis independent of any chemical hazard.
Chemical protective glove class
The EN 374 classification assigned by breakthrough time against a defined list of test chemicals, matching a glove to a specific substance rather than chemicals generally.

FAQ

Frequently asked questions about glove selection and suitability record

How is breakthrough time chosen for a task?+

Against how long the glove is actually worn in continuous or repeated contact with the substance, including incidental contact either side of the main step, with a comfortable margin. A short task against a long breakthrough time has margin to spare; a long task against a short one does not.

Can one glove protect against both chemical and mechanical hazards?+

Sometimes, but it needs verifying against both standards rather than assumed. A good EN 374 chemical rating has no bearing on EN 388 mechanical rating, and a task with both hazards present needs both checked.

Why would the correct chemical glove still cause dermatitis?+

Through occlusion: trapped sweat and heat irritate the skin over a long wear period regardless of how well the glove resists the chemical outside it. Worn continuously for a full shift, it can produce the skin condition it was specified to prevent.

Who should be consulted before a glove is finalised?+

The workers who wear it for the task, not just the person reading the data sheet. Dexterity, grip when wet, heat tolerance and fit across hand sizes cannot be judged from a specification; a trial is the only reliable way to surface a problem before it becomes a habit of removing the glove.

How often should a glove specification be reviewed?+

On a change to the chemical, the task, or a dermatitis case pointing at the current glove, and at a periodic review regardless. The trigger matters more than the interval, since a new chemical can make an adequate specification wrong immediately.

What does suitability confirmed mean if the glove is later found unsuitable?+

That the specification was a documented decision at the time, not a guarantee for all time. A later finding should trigger a new selection record rather than be treated as evidence the original decision was careless.

Keep going

Related templates and programmes

Siddarth Singh

Written and reviewed by

Siddarth Singh

Founder & Chief Executive Officer, Knowella

Certified Safety Professional and industrial and systems engineer with more than a decade inside food supply chain, freight and manufacturing operations. This page was written against the current text of the standards it cites, not against secondary summaries of them.

  • Certified Safety Professional (CSP), Board of Certified Safety Professionals
  • MBA, University of Chicago Booth School of Business
  • MS and BS, The Ohio State University, Industrial and Systems Engineering
  • Six Sigma Black Belt
Verify with BCSP →

Sources and last review. Reviewed 16 August 2026 against:

  • EN 374-1, protective gloves against dangerous chemicals and micro-organisms
  • EN 388, protective gloves against mechanical risks
  • EN 420, general requirements for protective gloves
  • OSHA 29 CFR 1910.138, Hand Protection (US)
  • EU Regulation 1935/2004 on materials intended to come into contact with food

This page is general guidance, not legal advice. Confirm requirements with your jurisdiction’s regulator.

Start in Minutes, Not Weeks

Launch a Ready-Made Template and Customize It Your Way

Every template is fully editable. Adjust fields, workflows, and branding to match your processes, then deploy to your team instantly.