What this is
What is a chemical storage inspection?
What is a chemical storage inspection?
A chemical storage inspection is a periodic physical check of a store, cabinet or bulk area, testing the storage conditions against the conditions the substances were assessed for. It examines access and security, ventilation, containment and drainage, container condition and labelling, separation of incompatible classes, emergency provision at the store, and the quantity held against the stated maximum. It verifies controls; it does not assess them.
Who should carry out a chemical storage inspection?
The area owner, monthly, with the competent person who wrote the segregation and quantity scheme reviewing the record rather than walking the store. The area owner knows what has arrived, what has been decanted and what has been pushed onto the bottom shelf since last month. What the area owner usually does not know is which classes may share a bund, which is why the scheme has to exist in writing first.
How often should chemical storage be inspected?
Monthly for a normal store, and event driven on top of that: a new substance entering the area, a change to the store or its ventilation, a spill or near miss, a change of supplier or pack size, any increase in quantity held. The interval catches drift; the events catch what makes last month's record wrong the day after it was signed.
Scope
When is a chemical storage inspection required?
This is a condition inspection of a storage location. It verifies that the controls the chemical assessment specified are still in place and still working. It does not decide what the controls should be, and it is not the instrument for anything held under pressure or in cylinders.
Use this template when
- The routine monthly check of a chemical store, day store, cabinet, bulk tank area or IBC bay
- A new substance has entered the area, or an existing one has changed pack size, supplier or concentration
- After a spill, leak or container failure, to check the store rather than only the incident
- After a change to the store itself: new shelving, altered ventilation, a new drain, a repositioned bund
- Before an external audit or regulator visit, where the state of the store will be walked
Do not use it for
- Compressed gas cylinders, which need SAF-036 Compressed Gas Inspection for valve protection, restraint, separation of fuel gas from oxygen and cylinder condition
- Testing the eyewash or drench shower itself, which belongs to SAF-031 Eyewash and Shower Inspection with its weekly activation and flow record
- Deciding whether a control is adequate, which is the chemical risk or COSHH assessment; this inspection verifies controls that have already been specified
- General tidiness, walkway obstruction and waste build-up, which belong to SAF-022 Housekeeping Inspection and will otherwise crowd out the chemical items
- Ignition source control and hazardous area classification in a flammable store, which is DSEAR or ATEX territory and needs an area classification drawing, not a checklist line
Compliance mapping
Which OSHA 1910.106 requirements does this satisfy?
Chemical storage is regulated by class rather than by activity: flammables, corrosives, oxidisers and toxics each pick up their own conditions, and the duties on labelling and data sheet access apply to all of them. The inspection is the routine evidence that those conditions still hold.
| Clause | Requirement | Where it lands |
|---|---|---|
| OSHA 1910.106(d)(3) | Inside storage room construction and ventilation, with a liquid-tight raised sill or ramp and drainage arranged so a release cannot escape the room | Storage condition |
| OSHA 1910.106(d)(4) | Design and construction of flammable liquid storage cabinets, with the quantity permitted per cabinet limited by class | Segregation |
| NFPA 400 | Segregation, separation or isolation of incompatible hazardous materials, with maximum allowable quantities per control area | Segregation |
| OSHA 1910.1200(f)(6) | Workplace containers labelled with the product identifier and words, pictures or symbols conveying the hazards | Containers and labelling |
| WHMIS 2015 (HPR SOR/2015-17) | Supplier label present, legible and intact for each hazardous product, with hazard pictograms and precautionary statements | Containers and labelling |
| OSHA 1910.1200(g)(8) | Safety data sheets readily accessible to employees in their work area, with no barrier to immediate access | Inventory check |
| OSHA 1910.151(c) | Suitable facilities for quick drenching or flushing of the eyes and body within the work area where corrosive materials may be encountered | Emergency provision |
| ISO 45001 cl.10.2 | Nonconformities reacted to, controlled and corrected, with the cause examined so the same deficiency does not recur | Observed deficiencies |
What it does not cover
- The chemical or COSHH assessment, which decides what the store must provide by examining the substance as used, and which this inspection only verifies against.
- DSEAR or ATEX area classification, which determines zones, equipment ratings and ignition source control in a flammable store and needs a classification drawing rather than a checklist item.
- Thorough examination and test of local exhaust ventilation, which under COSHH regulation 9 is a measured test at a stated interval; Ventilation Adequate says whether the store draws, not whether the extract meets its design duty.
- The spill response capability, which needs a plan, trained responders, a drill and a route for contaminated absorbent; a stocked spill kit is equipment, not an arrangement.
- Hazard communication training, which OSHA 1910.1200(h) and WHMIS both require to cover labels, data sheets and the specific products held, and which no inspection of the store evidences.
Global
Chemical Storage Inspection requirements by country
Every regime regulates chemical storage, and almost all of them do it through a mix of a general duty, class-specific quantity and construction rules, and a hazard communication system for labels and data sheets. What differs is where the quantity thresholds bite and who has to be told.
OSHA 1910.106; 1910.1200; 1910.151(c); NFPA 30 and NFPA 400 as adopted by fire code
Prescriptive quantity, construction and ventilation rules for flammables, with hazard communication duties across all hazardous chemicals.
Two authorities inspect the same store to different rulebooks, and the locally adopted fire code is often stricter on quantity per control area than 1910.106.
COSHH 2002 regulations 7 to 9; DSEAR 2002 regulations 5 and 6
Goal-setting duty to control exposure and to eliminate or reduce risk from dangerous substances, with control measures maintained and examined.
There is no line-by-line storage rule to point at, so the inspection record is the primary evidence that the assessed control measures are still in efficient working order.
CLP Regulation (EC) No 1272/2008; Chemical Agents Directive 98/24/EC; Seveso III Directive 2012/18/EU
Classification and labelling harmonised, exposure controls set by directive, major hazard thresholds triggered by aggregate quantity on site.
Crossing a Seveso lower-tier threshold by accumulating stock changes the regulatory regime for the whole site, which makes quantity held a compliance figure rather than a stock figure.
WHMIS 2015 via the Hazardous Products Regulations SOR/2015-17, with provincial OHS regulations and the Canada Labour Code Part II
Supplier labels and sixteen-section data sheets federally, workplace labelling, storage and worker education provincially.
The workplace label duty for a decanted container sits in provincial regulation, so relying on supplier labels alone fails the moment anything is transferred.
Model WHS Regulations Part 7.1 and Schedule 11
Register and manifest of hazardous chemicals, labelling, spill containment, and placarding once schedule quantities are exceeded.
Placarding and manifest duties are triggered by quantity, so an accurate figure in the inventory check is what tells you whether the store has crossed into a placarded regime.
GHS (UN Purple Book); ISO 45001 clauses 8.1.2 and 9.1.1
Common classification, labelling and data sheet format, with a management system duty to monitor whether controls are effective.
Auditors read the inspection series rather than one record, and a run of near-perfect scores with no findings reads as a control nobody is testing.
How to complete it
How to complete a chemical storage inspection, step by step
The form will produce a percentage from whatever is entered. Four judgement calls decide whether that percentage means anything, and none of them are prompted by a field label.
Before the first inspection, derive a segregation scheme from the hazard classes on the chemical register: which classes may share a shelf, which may share containment, which need a separate rated store. Then Incompatibles Separated, Oxidisers Separated From Fuels and Corrosives On Resistant Shelving become checks against a document. Without it they are three ways of recording one impression, and all three will say Pass.
N/A leaves the denominator, so it raises the percentage rather than leaving it neutral. Drainage Isolated From Store marked N/A because nobody could see the drain is not an exclusion, it is an unanswered question that has been rewarded. Use N/A only where the item genuinely cannot apply, and put the reason in the notes so the next inspector inherits the reasoning rather than the habit.
Quantity Held and Within Maximum only mean something against a limit attached to this location: the litres permitted in this cabinet, this room, this control area. Pulling the figure from the site register gives a total that is correct and irrelevant, because the constraint that matters is on the room the inspector is standing in. Where several cabinets share a room, the room limit governs and the cabinet figures have to be added.
Fixed On The Spot exists so an inspector can relabel a bottle and record it, not so the deficiency disappears. An item corrected during the walk and never entered is invisible to trending, and repeat labelling failures in one area are the signal worth having. Record it, mark it fixed, and raise a Finding ID only where the fix has to be tracked to closure.
What auditors find
Most common chemical storage inspection findings
Chemical store findings are rarely about missing paperwork. They are about the gap between the store as assessed and the store as it has drifted, and about inspections that scored the drift as a pass.
| Finding | Clause | What fixes it |
|---|---|---|
| Acids and hypochlorite or other oxidisers stored over shared secondary containment. | NFPA 400 | Separate the classes into their own containment per the segregation scheme and re-inspect before use. |
| Bund present but part full of rainwater, spilled product or stored stock, leaving no capacity. | COSHH 2002 reg.9 | Empty and clean the bund, and size the capacity to the largest single container plus a margin. |
| Decanted containers, spray bottles and dosing jugs without a workplace label. | OSHA 1910.1200(f)(6) | Label at the point of transfer with product identifier and hazard information; stock pre-printed labels at the store. |
| Product decanted into a food or drink container, or into an unmarked reused pack. | OSHA 1910.1200(f)(6) | Remove and dispose of the container; issue marked decant vessels and treat repeats as a discipline matter. |
| Flammable liquids held outside a rated cabinet or room, or above the quantity permitted per cabinet. | OSHA 1910.106(d)(4) | Move stock into rated storage and set a reorder quantity that cannot exceed the cabinet limit. |
| Store drainage connected to surface water or foul drain with no isolation. | OSHA 1910.106(d)(3) | Blank or seal the drain and provide a bunded route; record the isolation arrangement on the store drawing. |
| Safety data sheets not accessible at the work area, or held only in a system nobody at the store can reach. | OSHA 1910.1200(g)(8) | Provide immediate access at the store for every product held, and test it from the shop floor, not the office. |
| Data sheet on file superseded by a reformulated product with a different classification. | WHMIS 2015 (HPR SOR/2015-17) | Re-check the sheet at each delivery of a changed pack and update the register entry when classification changes. |
| Eyewash or drench facility beyond reach of the store, obstructed, or fed from a dead leg. | OSHA 1910.151(c) | Site the facility within the work area, keep the path clear, and hold the weekly activation record separately. |
| Same deficiency recorded in consecutive months with no finding raised and no owner. | ISO 45001 cl.10.2 | Raise a finding on the second occurrence with owner and date, and address the cause rather than the item. |
Case in point
Case in point: the store that scored 96 per cent for eleven months
A dairy site kept its CIP chemicals in an external store beside the pasteurising hall: caustic for the alkali wash, a nitric acid descaler, and sodium hypochlorite for terminal disinfection. The area owner inspected it monthly. Labels were good, the spill kit stocked, the data sheets in a weatherproof box on the door, and the score ran between 94 and 98 per cent. Incompatibles Separated was Pass every month. Bunding Or Containment Present was N/A, because the store had a sloped floor and nobody was sure whether that counted.
In the twelfth month a hypochlorite IBC developed a weep at the outlet valve. The liquid ran down the slope to the low corner, where a part-used 25 litre drum of the descaler had been left after a weekend clean with its cap on but not seated. Chlorine came off the mixture and drifted into the pasteurising hall through an open personnel door. Four people were treated for respiratory irritation and the site stopped for a day and a half.
The investigation found nothing wrong with the form. It found that nobody had written down which classes could share the store, so Pass on Incompatibles Separated meant the drums were on different shelves, which was true and beside the point once the floor connected them. The slope was not containment, it was a route. The corrective actions were a segregation scheme keyed to the register's hazard classes, kerbed separate containment for the acid, and a rule that N/A needs a reason in the notes.
The template
The template, field by field
The form exactly as it installs. Every field, option, score and conditional rule is editable, and the links to other templates come with it.
8 sections
- Reference
- SAF-035
- Archetype
- Inspection
- Record ID
- INSP-2026-000
- Scoring
- Percent with knockout items
- Direction
- High is good
- Singleton
- No
- Basis
- OSHA 1910.106, WHMIS 2015
- Links
- Links Substance; feeds Finding
- Tags
- Inspection, Chemical
- Sections
- 8
- Fields
- 59
- Follow up fields
- 9
- Repeating sections
- 2
- Links out
- 4
Header
8 fieldsInspection ID*
Auto sequence. Format INSP-2026-00000.
The record's own ID. Other templates point at this value.
Status*
Drives who this goes to next.
- Planned2 pts
- In progress2 pts
- Complete3 pts
- Deferred0 pts
- Open0 pts
- Closed3 pts
- Overdue0 pts
Date and Time*
Inspection Type*
Scheduled, unscheduled, follow up or post incident.
Site*
Site ID*
Format SITE-000.
Links to FDN-001 Site ID
Area*
The area within the site.
Exact Location
Drop a pin for anything hard to find.
Storage condition
6 fieldsStore Secure And Access Controlled*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Ventilation Adequate*
- Yes3 pts
- Marginal1 pt
- No0 pts
Lighting Adequate*
- Yes3 pts
- Marginal1 pt
- No0 pts
Bunding Or Containment Present*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Containment Empty And Serviceable*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Drainage Isolated From Store*
- Yes2 pts
- No0 pts
- N/Aexcluded from denominator
Containers and labelling
6 fieldsContainers In Good Condition*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
All Containers Labelled*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Secondary Containers Labelled*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Lids And Closures Secure*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
No Decanting Into Food Containers*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Stock Rotated*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Segregation
6 fieldsIncompatibles Separated*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Flammables In Rated Store*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Oxidisers Separated From Fuels*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Corrosives On Resistant Shelving*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Nothing Stored On The Floor*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Quantities Within Limit*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Emergency provision
6 fieldsSpill Kit Present And Suitable*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Eyewash Within Reach*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Safety Data Sheets Accessible*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
PPE Available At The Store*
- Yes2 pts
- No0 pts
- N/Aexcluded from denominator
Signage And Placarding Correct*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Fire Extinguisher Suitable*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
Inventory check
Repeats5 fieldsSubstance
Substance ID
Format SUB-0000.
Links to FDN-006 Substance ID
Quantity Held
Within Maximum*
- Pass2 pts
- Partial1 pt
- Fail0 pts
- N/Aexcluded from denominator
SDS Current*
- Yes2 pts
- No0 pts
- N/Aexcluded from denominator
Observed deficiencies
Repeats7 fieldsResult*
- Pass3 pts
- Pass with conditions2 pts
- Fail0 pts
Severity
- Minor3 pts
- Moderate1 pt
- Serious0 pts
Element Tag
Groups deficiencies by hazard type across every template.
Deficiency Detail
Photo Evidence
Fixed On The Spot
Finding ID
Raise a finding record where this needs tracking to closure.
Links to FDN-015 Finding ID
Result
15 fieldsItems Assessed*
Excludes anything marked N/A.
Items Failed*
Score Percent*
Calculated on submission. High is good. N/A items leave the denominator.
Result Band*
- Pass3 pts
- Caution1 pt
- Fail0 pts
Completeness Percent*
How much of the template was actually answered. A high score on a half completed form is not a high score.
Findings Raised
Highest Severity Found
- Observation3 pts
- Minor2 pts
- Major0 pts
Action Required*
Raise the action record, then enter its reference here.
- No2 pts
- Yes0 pts
Priority
- High0 pts
- Medium1 pt
- Low3 pts
CAPA ID
Format CAPA-2026-00000.
Links to FDN-014 CAPA ID
Action Owner
Next Inspection Due
Notes
Inspected By*
Signature*
SAF-035 · record IDs look like INSP-2026-000 · Links Substance; feeds Finding
Open in KnowellaRun it with agents
From a document you fill in to a programme that runs itself
The inspection is twenty minutes with a clipboard. What fails is around it: the new product that reached the shelf before it reached the register, the finding closed without anyone seeing the store, and the segregation scheme written once and never re-derived when the product range changed.
Holds the inspection schedule per store, routes each record to the area owner, and raises owned findings when the same deficiency reappears across rounds.

Watches the substance register for new products, changed classifications and quantity increases, and raises the store inspection before the monthly date when something has changed.
Connects containment and drainage findings to the site's discharge consents and spill response arrangements, so a bund failure is treated as a pollution risk as well as a safety one.
Ties hazard communication and product-specific training to the substances actually held in each area, so a new chemical produces a competency requirement rather than an assumption.
This template lives in KnowSafe — safety and compliance. Incidents, hazards, permits, inspections and the critical controls behind them.
Meet KnowSafe→Glossary
Chemical Storage Inspection definitions and key terms
- Incompatible materials
- Substances that react dangerously on contact, giving heat, gas, fire or a toxic product. Acid and hypochlorite, oxidiser and fuel, water-reactive and aqueous are the recurring pairs.
- Secondary containment
- A bund, sump, tray or kerbed floor sized to hold a release from the primary container. Its value is its remaining capacity, not its presence.
- Segregation scheme
- The written rule set, derived from the register's hazard classes, stating which classes may share a shelf, a bund or a room, and which must be separated or isolated.
- Workplace label
- The label required on a container filled in the workplace, carrying the product identifier and hazard information. Distinct from the supplier label it replaces.
- Flammable liquid storage cabinet
- A cabinet of specified construction permitting a limited quantity of flammable liquid in a work area, with the limit set per cabinet and per class.
- Maximum allowable quantity
- The quantity of a hazard class permitted in a control area before stricter construction or a dedicated store is required. It aggregates across cabinets in the same area.
- Safety data sheet
- The sixteen-section document covering hazards, handling, storage, first aid and spill response, required to be accessible where the product is used.
- Knockout item
- A scored line whose failure caps the whole record regardless of the percentage, used here for the items where a single failure makes the store unsafe.
FAQ
Frequently asked questions about chemical storage inspection
Can bleach and acid descaler be kept in the same store?+
Only where a written scheme has established that they are separated by containment as well as distance, and in most small stores that is not achievable. Sharing a shelf is obviously wrong; sharing a floor slope, a bund or a sump is the version that passes inspection and still produces chlorine. If the store cannot give each its own containment, they belong in different stores.
Does a plastic drip tray count as secondary containment?+
Only if its capacity matches the release it is there to catch. A tray under a 25 litre drum is containment; the same tray under a 200 litre drum is a mat. Size containment to the largest container in the group it serves, and record the capacity where the inspector can check it rather than assume it.
How much flammable liquid can be kept in the work area?+
Less than most sites hold. OSHA 1910.106(d)(4) limits the quantity in a cabinet by class, and the locally adopted fire code limits quantity per control area, which often binds first. Attach the limit to the reorder point in purchasing: a limit that lives only on an inspection form is discovered monthly and breached daily.
Are digital safety data sheets acceptable?+
Yes, provided access is immediate and unbarred from the work area. A tablet needing a login nobody on nights has, or a portal that is down when the network is, fails 1910.1200(g)(8) in substance. Test it the way a first aider would at 3am, and keep a paper set at high consequence stores.
Should the inspection cover gas cylinders in the same yard?+
No. Cylinders need their own instrument, because the failure modes are restraint, valve protection, separation of fuel gas from oxidiser and cylinder condition rather than containment and labelling. Recording them here produces a record that neither inspection can report on properly. Run SAF-036 alongside and cross-reference.
Is a high score evidence of a well run store?+
Not on its own. Read the score with Completeness Percent and the N/A count beside it, because both raise the percentage without improving the store. A record at 96 per cent with four N/A entries and no findings for a year is the profile that precedes most store incidents.
Keep going
Related templates and programmes
Industries this is written for
Programmes this belongs to
Used together in Workplace Inspection
Audit Finding Record
Records a single audit finding with its evidence, clause reference and classification
Finding
Records a single deficiency picked up during an audit, inspection or check
General Workplace Inspection
A broad walk through of an area covering the common hazards
Housekeeping Inspection
Checks that walkways, work areas and storage are clear, clean and in order
PPE Compliance Inspection
Checks that the right protective equipment is available, in good condition and being worn
Electrical Safety Inspection
Checks panels, cords, outlets and portable equipment for damage and safe access
More in Safety Inspections
General Workplace Inspection
A broad walk through of an area covering the common hazards
Housekeeping Inspection
Checks that walkways, work areas and storage are clear, clean and in order
PPE Compliance Inspection
Checks that the right protective equipment is available, in good condition and being worn
Electrical Safety Inspection
Checks panels, cords, outlets and portable equipment for damage and safe access
Ladder Inspection
Checks each ladder for damage, missing feet, loose rungs and correct labelling
Fall Arrest Equipment Inspection
Checks harnesses, lanyards and connectors for wear, damage and expiry

Written and reviewed by
Siddarth Singh
Founder & Chief Executive Officer, Knowella
Certified Safety Professional and industrial and systems engineer with more than a decade inside food supply chain, freight and manufacturing operations. This page was written against the current text of the standards it cites, not against secondary summaries of them.
- Certified Safety Professional (CSP), Board of Certified Safety Professionals
- MBA, University of Chicago Booth School of Business
- MS and BS, The Ohio State University, Industrial and Systems Engineering
- Six Sigma Black Belt
Sources and last review. Reviewed 16 August 2026 against:
- OSHA 29 CFR 1910.106(d) — container and portable tank storage of flammable liquids
- OSHA 29 CFR 1910.1200(f) and (g) — labels and other forms of warning; safety data sheets
- OSHA 29 CFR 1910.151(c) — medical services and first aid, quick drenching and flushing facilities
- WHMIS 2015 — Hazardous Products Regulations SOR/2015-17 (Canada)
- Control of Substances Hazardous to Health Regulations 2002, regulations 7 to 9 (GB)
- NFPA 30 Flammable and Combustible Liquids Code; NFPA 400 Hazardous Materials Code
- Model WHS Regulations Part 7.1 and Schedule 11 — hazardous chemicals, placarding and manifest quantities (Australia)
This page is general guidance, not legal advice. Confirm requirements with your jurisdiction’s regulator.