Knowella

Hand Arm Vibration Assessment

A hand arm vibration assessment measures exposure to vibration transmitted through hand-held and hand-guided tools into the hands and arms, and compares it against the daily exposure action and limit values. It is carried out per task and tool combination, not once for the workplace, and reviewed whenever the tool, task or trigger time changes. Its most common failure is the input, not the arithmetic: trigger time is guessed rather than timed, and the guess is almost always high, which makes every existing control look worse than it is.

KnowHealthAssessmentHLT-04147 fields across 5 sectionsFull researchSee the form

Reviewed by Siddarth SinghCSPLast reviewed 16 August 2026

Basis
ISO 45001 cl.6.1.2
Workspace
KnowHealth
Form type
Assessment
Assessed per
task and tool combination
Reviewed on
tool change, task change or symptom report

The short version

  • Hand arm vibration exposure is trigger time multiplied against magnitude, not tool type. Two workers on the same angle grinder can have very different exposure because one holds the trigger for forty minutes and the other for four.
  • Trigger time is normally estimated rather than measured, and the estimate runs high, because people report how long the job took rather than how long the tool was running. An assessment built on an estimate should say so.
  • The action and limit values are daily figures, normalised to an eight-hour reference period, A(8). A tool used briefly can sit below the action value even with a high declared magnitude.
  • A site measurement or trade association figure is more defensible than a declared magnitude, which is measured under standard conditions that rarely match a blunt consumable or worn bearing.
  • The hierarchy of controls applies here as everywhere: eliminating or mechanising the task, and a lower-vibration tool, both rank above anti-vibration gloves, which have limited proven effect.

What this is

What is a hand arm vibration assessment?

What is a hand arm vibration assessment?

A hand arm vibration assessment measures how much vibration a worker's hands and arms receive from a hand-held or hand-guided tool over a working day, and compares that exposure to the daily exposure action value (EAV) and exposure limit value (ELV). It combines the tool's magnitude with the actual trigger time, the time the tool is switched on and in contact with the hand, to produce a daily figure, usually expressed as A(8).

Who should carry out a hand arm vibration assessment?

A competent assessor, someone who understands the task, the tool and the magnitude data well enough to select a realistic figure and combine it with a measured trigger time. Competence here is judgement in combining exposure data, not a measurement qualification.

When is a hand arm vibration assessment reviewed?

Whenever the tool changes, the task changes materially, or trigger time turns out different from what was assumed. A fixed review date is a backstop; the assessment is wrong the moment a heavier tool replaces a lighter one and nobody re-runs the numbers.

Scope

When is a hand arm vibration assessment required?

This assessment is specific to hand-held and hand-guided tools. Vibration reaching the body through a seat or vehicle floor is a different pathway and belongs to the whole body vibration assessment, not this one.

Use this template when

  • A tool that transmits vibration into the hands is introduced, or its use changes materially in duration or frequency
  • The trigger time or magnitude source for an existing tool-task combination needs re-establishing
  • You are running the Occupational Health Surveillance programme and this is one of its steps
  • A worker reports symptoms consistent with hand-arm vibration syndrome and the exposure needs re-checking
  • A linked record needs this one to exist: the tool register or health surveillance plan

Do not use it for

  • Whole Body Vibration Assessment, which covers vibration through a seat or vehicle floor from driving, not through the hands
  • Vibration Health Surveillance Record, which records tiered health surveillance for exposed workers, from questionnaire through to clinical assessment
  • Tool Vibration Register, which holds the magnitude and trigger time limit for every tool in use, and is the source this assessment should draw its magnitude from
  • A general risk assessment, which will not quantify daily exposure against the action and limit values the way this one does
  • Anything outside KnowHealth, which belongs in the workspace that owns that process

Compliance mapping

Which ISO 45001 cl.6.1.2 requirements does this satisfy?

Hand-arm vibration is one of the few hazards with numeric legal thresholds attached to the assessment, which makes method matter as much as record.

ClauseRequirementWhere it lands
ISO 5349-1Measurement and assessment of hand-transmitted vibration, defining A(8) and frequency-weighted magnitudeHeader
EU Directive 2002/44/EC art.4Assessment of vibration risk at the workplace, including magnitude and duration of exposureExposure
Control of Vibration Regs 2005 reg.4Assessment of the risk to employees from vibration, reviewed when no longer validExposure
ISO 45001 cl.6.1.2.1Hazard identification proactive and ongoing, covering conditions that raise exposure beyond rated magnitudeFactors that raise exposure
Control of Vibration Regs 2005 reg.6Elimination or reduction of risk via the hierarchy of controls, tool selection before PPEControls
Control of Vibration Regs 2005 reg.7Health surveillance for employees likely exposed above the action valueOutcome
ISO 45001 cl.9.1.1Monitoring and measurement of control effectiveness, including the tool register this feedsOutcome

What it does not cover

  • Whole body vibration assessment, a different exposure pathway (seat or floor, not hand-held tool) with different contributing factors (surface and seat, not grip force and posture).
  • Tool vibration register, which holds the underlying magnitude and trigger time data this assessment draws on; it consumes the register, it does not replace it.
  • Vibration health surveillance, the clinical tier triggered once exposure crosses the action value, run once this assessment has flagged the need.
  • A general risk assessment, which will not quantify daily exposure against the action and limit values or apply the required frequency-weighting.
  • Dermatitis or glove-suitability assessment, hand protection for a different hazard, not to be conflated with anti-vibration glove selection here.

Global

Hand Arm Vibration Assessment requirements by country

Numeric thresholds exist in law across the EU and UK for hand-arm vibration, while the US relies on general duty and voluntary guidance.

United States

OSH Act General Duty Clause; ACGIH Threshold Limit Value

No OSHA standard sets a numeric limit for hand-arm vibration; ACGIH's TLV is voluntary guidance, not law.

Enforcement runs through the General Duty Clause; ignoring an ACGIH-consistent programme is a weaker defence, not a breach itself.

United Kingdom

Control of Vibration at Work Regulations 2005

Exposure action value 2.5 m/s² A(8) and exposure limit value 5.0 m/s² A(8), with assessment and surveillance above the EAV.

The thresholds are set in law, making the trigger-time and magnitude inputs directly load-bearing rather than advisory.

International

ISO 5349-1 and ISO 45001 cl.6.1.2

ISO 5349-1 defines the measurement behind A(8); ISO 45001 requires the underlying hazard identification.

Where no national threshold applies, ISO 5349-1 is still the reference most trade and manufacturer data is built on.

How to complete it

How to complete a hand arm vibration assessment, step by step

The form prompts for a magnitude, a trigger time and a set of yes/no factors. What determines whether the exposure figure means anything is how those first two numbers were obtained.

Time the trigger, don't estimate the job

Ask how long the tool was switched on and in the worker's hand, not how long the job took. Job duration includes positioning, changeover and waiting, so the estimate runs high, or occasionally low where intermittent use is forgotten. A rough stopwatch reading beats a recalled estimate.

Prefer a measured or trade-association magnitude over the manufacturer's declared figure

A declared magnitude is measured on a new tool under standard conditions. A blunt consumable, worn bearing or poorly maintained tool can raise the real figure well above it, so record which source was used and why.

Work down the hierarchy before anti-vibration gloves

Record why eliminating or mechanising the task and a lower-vibration tool were rejected before gloves are proposed. Gloves have limited attenuation at the relevant frequencies, and reaching for them first skips the controls most likely to reduce exposure.

Feed the tool register and health surveillance trigger from the same record

The exposure category should update the tool register so the next assessor starts from real data, and raise surveillance the moment exposure crosses the action value rather than waiting for a separate decision.

What auditors find

Most common hand arm vibration assessment findings

The assessment almost always exists once a vibration programme runs. The findings concern the reliability of its two central inputs and whether the outcome changed anything.

FindingClauseWhat fixes it
Trigger time estimated from job duration rather than measured or timed.ISO 5349-1Time the tool's actual on-trigger duration across a representative task.
Manufacturer's declared magnitude used without checking against site measurement or the tool register.Control of Vibration Regs 2005 reg.4Use a site measurement or trade figure where available, and record the source.
Assessment concludes in anti-vibration gloves without recording why elimination, mechanisation or a lower-vibration tool were rejected.Control of Vibration Regs 2005 reg.6Document the hierarchy of controls reasoning before PPE is proposed.
Exposure above the action value but health surveillance not triggered.Control of Vibration Regs 2005 reg.7Link the exposure category directly to the surveillance requirement.
Tool register not updated with the assessed magnitude and trigger time limit.ISO 45001 cl.9.1.1Update the register from the outcome as a closing step, not an optional one.
Assessment not reviewed when the tool or task changed.ISO 45001 cl.6.1.2.1Trigger review on tool or task change, not only at the stated interval.

Case in point

Case in point: the grinder that looked fine on paper

A fabrication shop assessed angle grinder use for weld dressing. The assessor used the manufacturer's declared magnitude and asked how long the job took, then estimated trigger time from a standard shift pattern. Exposure came out below the action value, and the assessment concluded with a maintenance reminder and no further action.

A later review, prompted by a worker reporting tingling in his fingers, timed the actual trigger use across a shift and found the grinder was live nearly three times the estimated duration, because the job involved short bursts the operator hadn't counted as 'the tool running'. Recalculated, exposure sat above the action value. The magnitude figure was never the problem; the estimate of how long the tool ran was.

The template

The template, field by field

The form exactly as it installs. Every field, option, score and conditional rule is editable, and the links to other templates come with it.

47fields
5 sections
Reference
HLT-041
Archetype
Assessment
Record ID
HAV-2026-000
Scoring
Exposure points
Direction
Low is good
Singleton
No
Basis
ISO 45001 cl.6.1.2
Links
Links Tool register, Health surveillance
Tags
Vibration
Sections
5
Fields
47
Follow up fields
3
Repeating sections
0
Links out
4
Field typesOwn ID, generated on saveCase thread and parentPick list from a registryLinked to another templateFollow up, dashed outlineScored

Header

13 fields
Text

Assessment ID*

Generated on save

Auto sequence. Format HAV-2026-000.

The record's own ID. Other templates point at this value.

Single Choice

Status*

Scored

Drives who this goes to next.

  • Planned2 pts
  • In progress2 pts
  • Complete3 pts
  • Deferred0 pts
  • Open0 pts
  • Closed3 pts
  • Overdue0 pts
Date & Time

Date and Time*

Users

Completed By*

Pick List

Site*

From FDN-001 Site NameFilter: Status is Active
Text

Site ID*

Linked

Format SITE-000.

Links to FDN-001 Site ID

Text

Task Assessed*

Single Choice

Tool Type*

Angle grinderImpact wrenchNeedle gunSawDrillBreakerSanderBandsaw
Numeric Answer

Workers Exposed*

Scored
Single Choice

Vibration Magnitude Source*

Scored
  • Site measurement4 pts
  • Trade association data3 pts
  • Manufacturer declared1 pt
  • Estimated0 pts
Numeric Answer

Declared Magnitude*

Scored
Numeric Answer

Daily Trigger Time Minutes*

Scored
Info

Trigger Time Is What Almost Nobody Measures

Exposure depends on how long the tool is actually running, not how long the job takes. People guess, and they guess high, which makes every control look inadequate.

Exposure

6 fields
Single Choice

Trigger Time Measured Not Estimated*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Magnitude From Site Measurement*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Tool Register Value Used*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Exposure Points Calculated*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Above Exposure Action Value*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Above Exposure Limit Value*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts

Factors that raise exposure

6 fields
Single Choice

Tool Poorly Maintained*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Blunt Or Worn Consumables*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Excessive Grip Force Needed*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Cold Working Conditions*

Scored
  • No3 pts
  • Some1 pt
  • Constant0 pts
Single Choice

Awkward Posture While Using*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Tool Held Rather Than Supported*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts

Controls

6 fields
Single Choice

Task Could Be Eliminated Or Mechanised*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Lower Vibration Tool Available*

Scored
  • Yes3 pts
  • Being explored1 pt
  • No0 pts
Single Choice

Tool Maintenance Schedule In Place*

Scored
  • Yes2 pts
  • No0 pts
  • N/Aexcluded from denominator
Single Choice

Job Rotation Applied*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Anti Vibration Gloves Considered*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Single Choice

Workers Trained On Symptoms*

Scored
  • Yes2 pts
  • No0 pts
  • N/Aexcluded from denominator

Outcome

16 fields
Single Choice

Exposure Category*

Scored
  • Below action value4 pts
  • Between action and limit1 pt
  • Above limit value0 pts
Single Choice

Assessment Action Required*

Scored
  • None3 pts
  • Monitor2 pts
  • Improve1 pt
  • Act now0 pts
Date & Time

Next Review Due*

Single Choice

Health Surveillance Required*

YesNo
Text

Surveillance Record ID

OptionalLinked

Links to HLT-043 Record ID

Single Choice

Tool Register Updated*

Scored
  • Yes3 pts
  • Partly1 pt
  • No0 pts
Pick List

Risk Assessment

OptionalFrom FDN-012 Risk Title
Text

Risk ID

OptionalLinked

Format RSK-2026-00000.

Links to FDN-012 Risk ID

Single Choice

Action Required*

Scored

Raise the action record, then enter its reference here.

  • No2 pts
  • Yes0 pts
Single Choice

Priority

OptionalScoredShows if Action Required equals Yes
  • High0 pts
  • Medium1 pt
  • Low3 pts
Text

CAPA ID

OptionalLinkedShows if Action Required equals Yes

Format CAPA-2026-00000.

Links to FDN-014 CAPA ID

Users

Action Owner

OptionalShows if Action Required equals Yes
Users

Assessor*

Signature

Signature*

Users

Safety Lead*

Signature

Second Signature*

HLT-041 · record IDs look like HAV-2026-000 · Links Tool register, Health surveillance

Open in Knowella

Run it with agents

From a document you fill in to a programme that runs itself

The exposure figure depends on two inputs nobody times well. The agents here exist to catch the tool that changed and the review that never happened, not to recompute the arithmetic.

KnowHealth

Holds the assessment against the tool register and health surveillance plan, flags exposure above the action value, and routes review when a tool changes.

KnowSafe

Links the outcome to the risk register and CAPA, so an 'act now' category produces a tracked action rather than a flagged field nobody follows up.

KnowTrain

Connects the workers-trained-on-symptoms field to an actual training record, so awareness is evidenced rather than assumed.

Ella
Ella

Watches for tool, task and symptom reports that should trigger a review, and raises it rather than waiting for the stated interval.

This template lives in KnowHealth — employee wellbeing. Exposure monitoring, health surveillance, case management and return to work.

Meet KnowHealth→

Glossary

Hand Arm Vibration Assessment definitions and key terms

Exposure action value (EAV)
The daily exposure, A(8), at which an employer must act and, in the UK, offer surveillance: 2.5 m/s² for hand-arm vibration.
Exposure limit value (ELV)
The daily exposure that must not be exceeded: 5.0 m/s² A(8) for hand-arm vibration under UK regulations.
A(8)
Daily exposure normalised to an eight-hour period, combining magnitude and trigger time.
Trigger time
The time a tool is actually switched on and in contact with the hand, distinct from the time spent on the wider job.
Vibration magnitude
The frequency-weighted acceleration a tool produces, in m/s², sourced from measurement, trade data or the manufacturer's declaration.

FAQ

Frequently asked questions about hand arm vibration assessment

Do anti-vibration gloves reduce exposure enough to rely on?+

Not reliably. Gloves have limited proven attenuation at the relevant frequencies and should be supplementary at most, considered after eliminating the task or specifying a lower-vibration tool, not instead of those steps.

What if trigger time can't be measured directly?+

Observe a sample of the task and time the tool's on-trigger periods, rather than asking the operator to estimate job duration. An approximate measured figure beats a recalled estimate, which is biased upward or, for intermittent tasks, downward.

Which magnitude figure should be used?+

A site measurement is most reliable, then trade association data, then the declared figure, used cautiously since it is measured under conditions a blunt or poorly maintained tool will exceed.

Does exceeding the exposure limit value mean the tool must stop being used immediately?+

It means exposure must be brought below the limit value, usually through an immediate change to trigger time, tool or method rather than a scheduled review. The limit value is a ceiling, not a target.

How does this assessment connect to health surveillance?+

Exposure above the action value normally triggers health surveillance, and the outcome should raise that requirement directly rather than depend on someone checking the exposure category separately.

How often is this assessment reviewed?+

Whenever the tool or task changes materially, or a symptom report suggests the exposure assumption was wrong, with a stated review date as the backstop rather than the primary trigger.

Keep going

Related templates and programmes

Siddarth Singh

Written and reviewed by

Siddarth Singh

Founder & Chief Executive Officer, Knowella

Certified Safety Professional and industrial and systems engineer with more than a decade inside food supply chain, freight and manufacturing operations. This page was written against the current text of the standards it cites, not against secondary summaries of them.

  • Certified Safety Professional (CSP), Board of Certified Safety Professionals
  • MBA, University of Chicago Booth School of Business
  • MS and BS, The Ohio State University, Industrial and Systems Engineering
  • Six Sigma Black Belt
Verify with BCSP →

Sources and last review. Reviewed 16 August 2026 against:

  • ISO 5349-1:2001, Measurement and assessment of human exposure to hand-transmitted vibration
  • Control of Vibration at Work Regulations 2005 (UK), regulations 4, 6 and 7
  • EU Directive 2002/44/EC on exposure to vibration
  • ISO 45001:2018 clauses 6.1.2 and 9.1.1

This page is general guidance, not legal advice. Confirm requirements with your jurisdiction’s regulator.

Start in Minutes, Not Weeks

Launch a Ready-Made Template and Customize It Your Way

Every template is fully editable. Adjust fields, workflows, and branding to match your processes, then deploy to your team instantly.