What this is
What is an office ergo follow up?
What is an office ergo follow up?
A follow-up review carried out some weeks after an office ergonomic change, checking whether the change is still in place, whether the equipment is actually being used, and whether the discomfort it was meant to address has improved. It exists because supplying equipment is not the same as fixing the problem.
Who should carry out the follow up?
Ergonomics, together with the worker. The worker is the only person who knows whether the chair setting has drifted back or the new keyboard tray is in the way of something else, and the ergonomics function is the one qualified to judge whether a reported improvement is genuine or partial.
Why not just ask if the problem is fixed?
Because a single yes-or-no question conflates three different failures: the change was never implemented, it was implemented but abandoned, or it was implemented and used but did not touch the actual cause of the discomfort. Each has a different fix, and a follow-up that does not separate them cannot tell you which one you have.
Scope
When is an office ergo follow up required?
This review is one step in a larger programme, and it sits specifically after an office ergonomic change has been made. Using it before a change exists, or in place of the initial assessment, produces a record with nothing to follow up on.
Use this template when
- An office ergonomic change, new chair, monitor arm, keyboard tray or desk setting, was made 30 to 60 days ago
- A worker reported a barrier to using equipment that was supplied and this needs to be recorded and actioned
- The original discomfort or symptom needs to be tracked to resolution, improvement, or referral
- A prior follow-up left an action open, or scheduled a further check, and that date has arrived
- The Ergonomics and MSD Prevention programme requires proof that a redesign actually worked, for the business case
Do not use it for
- Office Workstation Self Assessment, which lets a worker assess their own desk setup and is the input, not the check on whether a prior change held
- Display Screen Assessment, which assesses screen height, distance and glare and belongs before a change is recommended, not after
- Remote Work Assessment, which covers a home setup from photographs and is a different assessment channel entirely
- Task Ergonomic Assessment, which is the original assessment that identified the risk this follow-up is checking the fix for
- Anything outside KnowErgo, which belongs in the workspace that owns that process
Compliance mapping
Which ISO 45001 cl.9.1 requirements does this satisfy?
Nothing requires an office ergo follow up by this name. The obligation it discharges is the general management-system duty to check that a control, once put in place, is actually working and stays working.
| Clause | Requirement | Where it lands |
|---|---|---|
| ISO 45001 cl.9.1.1 | Monitoring and measurement of the effectiveness of controls implemented to address risk | Outcome |
| ISO 45001 cl.8.1.2 | Controls are maintained, not just implemented once; a control that has been removed or bypassed is a control failure | Is it working |
| HSE DSE Regs 1992 (as amended), reg.2 | Workstation assessment must be reviewed when there is reason to think it is no longer valid | Header |
| ISO 45001 cl.10.2 | Nonconformity is acted on with a corrective action that has an owner and is verified, not just closed | Outcome |
| ISO 45001 cl.5.4 | Consultation and participation of workers in matters affecting their health and safety | Is it working |
| ISO 45001 cl.6.1.2.1 | Hazard identification is ongoing, including hazards that emerge as a result of a change already made | Symptoms |
What it does not cover
- Office Workstation Self Assessment, which is the worker's own guided assessment of their desk setup and precedes any change this follow-up checks.
- Task Ergonomic Assessment, which establishes the original risk rating and recommended controls that this record is verifying.
- Display Screen Assessment, which is the screen-specific assessment of height, distance and glare, not a check on whether a prior fix held.
- MSD Injury Report, which is the record of an actual musculoskeletal injury and belongs in the incident system, not in a follow-up review.
- Early Intervention Record, which captures the first response to a new discomfort report, a distinct step from checking on a change already made.
Global
Office Ergo Follow Up requirements by country
No jurisdiction names an office ergo follow up as a legal instrument. What each regime supplies is the underlying duty to review a workstation assessment when there is reason to think it no longer holds.
OSH Act General Duty Clause; no general DSE-specific standard
No federal requirement to follow up on office ergonomic changes by name.
Enforcement for an uncorrected office hazard runs through the General Duty Clause, so a follow-up that never happens leaves the original finding unresolved.
Health and Safety (Display Screen Equipment) Regulations 1992, reg.2
Assessment must be reviewed if no longer valid, or if there has been a significant change to the workstation.
A follow-up finding reverted settings is, in effect, the trigger the regulation contemplates for a fresh assessment.
ISO 45001
Management system requirement to monitor and measure effectiveness of implemented controls and act on nonconformity.
An auditor will ask for evidence a recommended control was checked after implementation, not just recommended.
How to complete it
How to complete an office ergo follow up, step by step
The form's questions are simple by design. What makes the record defensible is how the assessor interprets a mixed or ambiguous answer, which the form itself does not resolve.
"Changes still in place", "equipment being used" and "discomfort improved" are three different questions, and a change can pass one while failing another. Collapsing them into a single impression misses the case where the chair is adjusted but the worker has quietly stopped using the footrest that mattered most.
"Uncomfortable", "gets in the way" and "never shown how" point to three different corrective actions: a different item, a redesign, or training. Recording only that equipment is unused, without the reason, produces a repeat of the same failed intervention.
An email or form relies on the worker noticing and reporting drift, which they usually only do once discomfort has already returned. A short in-person check catches a reverted chair height before it becomes a symptom, which is the point of running the follow-up at all.
Discomfort can improve while the change itself has reverted, and the improvement will not survive the worker's next long week. Closure should require the change to still be in place and in use, not just a favourable answer on the symptom question.
What auditors find
Most common office ergo follow up findings
Because this record almost always exists on schedule, the findings concern what the follow-up actually checked, rather than whether it happened.
| Finding | Clause | What fixes it |
|---|---|---|
| Follow-up completed by email or form only, with no verification that settings held. | ISO 45001 cl.9.1.1 | Require an in-person or video check for any case with a prior high-risk rating or reported barrier. |
| Equipment recorded as supplied with no check on whether it is actually being used. | ISO 45001 cl.8.1.2 | Ask the worker to demonstrate current use, not just confirm receipt of the item. |
| Case closed while discomfort is recorded as only partly improved. | ISO 45001 cl.10.2 | Route partly-improved outcomes to a scheduled next follow-up rather than closure. |
| New symptoms elsewhere recorded but not escalated to further assessment. | ISO 45001 cl.6.1.2.1 | Treat a new symptom as a fresh hazard indicator and route it to a task ergonomic assessment. |
| Barrier to use identified with no reason captured, so the same item is issued again unchanged. | ISO 45001 cl.10.2 | Record the specific barrier reason and match the corrective action to it. |
| Follow-up run well outside the 30 to 60 day window, either too early to show habituation or too late to catch drift. | ISO 45001 cl.9.1.1 | Schedule the follow-up date at the point the original change is made, not left to be booked later. |
Case in point
Case in point: the follow-up that ticked a box
A worker was issued a monitor arm and an adjustable keyboard tray after a wrist complaint. The follow-up went out as an email form six weeks later. The worker answered that the equipment was in place, ticked "resolved" for the wrist, and the case was closed the same day.
Three months on, the worker reported a new shoulder complaint. A site visit as part of that investigation found the monitor arm had never actually been reattached after a desk move, and the worker had been resting the keyboard on a stack of files at an angle that loaded the shoulder instead of the wrist. The original follow-up had been answered honestly, but from memory of what was supposed to have happened rather than what the desk currently looked like.
The template
The template, field by field
The form exactly as it installs. Every field, option, score and conditional rule is editable, and the links to other templates come with it.
4 sections
- Reference
- ERG-020
- Archetype
- Review
- Record ID
- OFU-2026-000
- Scoring
- Improvement rating
- Direction
- High is good
- Singleton
- No
- Basis
- ISO 45001 cl.9.1
- Links
- Links Assessment, Worker
- Tags
- Ergonomics, Office, Verification
- Sections
- 4
- Fields
- 34
- Follow up fields
- 3
- Repeating sections
- 0
- Links out
- 3
Header
13 fieldsRecord ID*
Auto sequence. Format OEF-2026-000.
The record's own ID. Other templates point at this value.
Status*
Drives who this goes to next.
- Planned2 pts
- In progress2 pts
- Complete3 pts
- Deferred0 pts
- Open0 pts
- Closed3 pts
- Overdue0 pts
Date and Time*
Completed By*
Site*
Site ID*
Format SITE-000.
Links to FDN-001 Site ID
Area
The area within the site.
Exact Location
Drop a pin for anything hard to find.
Worker*
Person ID*
Format PER-0000.
Links to FDN-003 Person ID
Original Record ID*
Immediate predecessor record
Weeks Since Change*
Follow Up Method*
- In person3 pts
- Phone or video2 pts
- Email or form1 pt
Is it working
5 fieldsChanges Still In Place*
- Yes3 pts
- Partly1 pt
- No0 pts
Equipment Being Used*
- Yes3 pts
- Sometimes1 pt
- No0 pts
Settings Unchanged*
- Yes3 pts
- Drifted1 pt
- Reverted0 pts
Reason If Not Used
Uncomfortable, unsuitable, gets in the way, never shown how, or the problem changed.
Barrier Detail
Symptoms
3 fieldsDiscomfort Improved*
- Resolved3 pts
- Improved2 pts
- No change0 pts
- Worse0 pts
Current Discomfort Level
New Symptoms Elsewhere*
Fixing the wrist and creating a shoulder problem is a common outcome of a partial change.
- No3 pts
- Yes0 pts
Outcome
13 fieldsIntervention Effective*
- Yes3 pts
- Partly1 pt
- No0 pts
Further Assessment Needed*
- No3 pts
- Yes1 pt
Referral Needed*
- No3 pts
- Yes1 pt
Case Closed*
- Yes3 pts
- No1 pt
Next Follow Up
Action Required*
Raise the action record, then enter its reference here.
- No2 pts
- Yes0 pts
Priority
- High0 pts
- Medium1 pt
- Low3 pts
CAPA ID
Format CAPA-2026-00000.
Links to FDN-014 CAPA ID
Action Owner
Assessor*
Signature*
Worker*
Second Signature*
ERG-020 · record IDs look like OFU-2026-000 · Links Assessment, Worker
Open in KnowellaRun it with agents
From a document you fill in to a programme that runs itself
The form asks the right three questions. What slips is the check itself: the follow-up that goes out on schedule but never gets an honest look at the desk.
Schedules each follow-up against the date the original change was made, and flags any case closed without a confirmed in-place, in-use, and discomfort outcome.
Tracks new symptoms elsewhere reported on a follow-up back into the wider symptom and injury record, so a compensatory strain is not lost as a footnote.
Picks up a "never shown how" barrier and turns it into a scheduled equipment demonstration rather than a repeat issue of the same item.

Watches for follow-ups run outside the 30 to 60 day window or closed on a partial outcome, and raises them for review before the case is signed off.
This template lives in KnowErgo — ergonomics. Task assessment, video posture analysis, rotation and workstation redesign.
Meet KnowErgo→Glossary
Office Ergo Follow Up definitions and key terms
- Habituation
- The period a worker needs to adjust posture and behaviour to a new setup, before an evaluation of its effect is meaningful.
- Settings drift
- Gradual reversion of an adjusted setting, chair height, monitor distance, back toward its pre-change position without a deliberate decision to revert it.
- Compensatory strain
- A new symptom that appears at a different body site after a change addressed the original one, usually because only part of the workstation was corrected.
- Intervention effectiveness
- Whether a specific control, once implemented and used as intended, actually reduced the risk it was chosen to address.
- Residual discomfort
- The level of discomfort remaining after a change, distinct from whether the change itself is still in place.
FAQ
Frequently asked questions about office ergo follow up
How soon after a change should the follow-up happen?+
Thirty to sixty days. Earlier and the worker has not had time to habituate to the new setup, so any reported comfort is unreliable. Later and a reverted setting or abandoned item has stopped registering as a change at all, and gets reported as normal.
What if the equipment is in place but not being used?+
Record it as a distinct outcome, not the same failure as the equipment never having arrived. An item present but unused points to discomfort, unsuitability, or a training gap, each needing a different corrective action from a missing item.
Should the follow-up be done in person or by form?+
In person or by video where the original risk was significant or a barrier has already been reported. Drift and disuse are usually visible rather than reported, and a form only catches what the respondent remembers to mention.
What does a new symptom elsewhere mean for the case?+
That the intervention addressed one contributing factor and left another uncorrected. Fixing the wrist and loading the shoulder is common enough that it should route to further assessment, not be logged as a caveat on an otherwise closed case.
When should the case be closed?+
When the change is confirmed still in place, the equipment confirmed in use, and discomfort resolved or meaningfully improved with no new symptoms elsewhere. A favourable discomfort answer alone is not sufficient grounds to close.
Who should carry out the check?+
Ergonomics, working with the worker directly rather than through a form alone wherever the original risk warranted it. The worker knows what actually changed day to day; ergonomics judges whether that is a genuine fix.
Keep going
Related templates and programmes
Industries this is written for
Programmes this belongs to
Used together in Ergonomics and MSD Prevention
Discomfort Report
Lets a worker report aches, pain or discomfort early, before it becomes an injury
Body Part Symptom Survey
Maps where in the body workers are experiencing discomfort, across a team or area
MSD Injury Report
Records a diagnosed musculoskeletal injury, including affected body part and suspected task
Early Intervention Record
Records the actions taken when discomfort is reported, before it becomes an injury
MSD Trend Review
Reviews discomfort reports and MSD injuries across areas and tasks
Task Ergonomic Assessment
Assesses a work task using video, applying the methods you configure such as RULA, REBA or WISHA
More in Office Ergo
Office Workstation Self Assessment
Lets an office worker assess their own desk setup using guided questions and reference images
Display Screen Assessment
Assesses screen height, distance, glare and eye comfort for computer based work
Remote Work Assessment
Assesses a home or remote work setup using photographs supplied by the worker
Ergonomic Equipment Request
Requests equipment such as a chair, monitor arm, footrest or sit stand desk
Workstation Setup Record
Records how a workstation was adjusted and set up for a specific person

Written and reviewed by
Siddarth Singh
Founder & Chief Executive Officer, Knowella
Certified Safety Professional and industrial and systems engineer with more than a decade inside food supply chain, freight and manufacturing operations. This page was written against the current text of the standards it cites, not against secondary summaries of them.
- Certified Safety Professional (CSP), Board of Certified Safety Professionals
- MBA, University of Chicago Booth School of Business
- MS and BS, The Ohio State University, Industrial and Systems Engineering
- Six Sigma Black Belt
Sources and last review. Reviewed 16 August 2026 against:
- ISO 45001:2018 clauses 9.1.1, 8.1.2, 10.2, 6.2 and 5.4
- Health and Safety (Display Screen Equipment) Regulations 1992 (as amended), regulation 2 (UK)
- OSH Act Section 5(a)(1), General Duty Clause (US)
- HSE guidance on display screen equipment workstation assessment
This page is general guidance, not legal advice. Confirm requirements with your jurisdiction’s regulator.