Knowella

Unsafe Condition Report

The failure mode is rarely that nobody noticed. It is that somebody noticed, fixed it on the spot with a cable tie and a cone, and never wrote it down. The guard on the same slicer gets refitted four times a year, each time in ten minutes, and the maintenance history shows nothing. When the fifth failure takes a finger, the organisation finds it has no record the condition ever recurred, and no basis for arguing it was controlled.

KnowSafeRecordSAF-014Pinned in navigation24 fields across 4 sectionsFull researchSee the form

Reviewed by Siddarth SinghCSPLast reviewed 16 August 2026

Basis
ISO 45001 cl.6.1.2
Workspace
KnowSafe
Form type
Record
Raised by
Anyone on site, at the moment the condition is seen
Closed by
The area owner, who signs whether it was fixed or routed onward

The short version

  • The value of this record is recurrence data, not the individual fix. A condition repaired on the spot and never logged is invisible to the analysis that would justify replacing the failing component.
  • Urgency and Area Isolated must move together. An Immediate rating with Area Isolated set to No is a self-documented failure to act on your own assessment.
  • Fixed Immediately and Action Required answer different questions: whether the hazard is gone, and whether the reason it appeared is still there. Both can be Yes.
  • Linking the report to an asset converts one-off reports into a maintenance argument. Without it, the same failure on the same machine is indistinguishable from thirty unrelated events.

What this is

What is an unsafe condition?

What is an unsafe condition?

An unsafe condition is a physical state of the workplace, plant or environment that creates risk regardless of how anyone behaves around it: a missing guard, a blocked fire exit, a failed luminaire, standing water on a walkway. It differs from an unsafe act in where the fault sits. The condition persists whether or not a person is present, so the control must be engineered or repaired rather than instructed.

How does an unsafe condition report differ from a hazard report?

A hazard report describes a source of harm in general terms, often as part of a planned assessment. An unsafe condition report is narrower and always reactive: something previously acceptable has degraded, broken or been obstructed. A hazard feeds risk assessment; a condition feeds a work order. Filing one as the other lands the record in a queue nobody manages.

What does ISO 45001 cl.6.1.2 require of hazard identification?

Clause 6.1.2 requires an ongoing and proactive process for identifying hazards, explicitly including those arising from infrastructure, equipment, materials and the physical conditions of the workplace. The word carrying the weight is ongoing. A process that identifies hazards only during a scheduled audit cannot see conditions that arise and are cleared between audits.

Scope

When is an unsafe condition report required?

This record covers physical conditions that have degraded and need restoring. It sits between the person who sees the problem and the person who holds the spanner, and is short enough to complete standing in front of the condition.

Use this template when

  • A guard, interlock, handrail, floor surface or lighting installation has failed or been removed and not replaced
  • A means of escape, fire point or electrical panel is obstructed
  • A spill, leak or accumulation creates a slip, trip or contamination risk
  • Plant is leaking, running hot, carrying damaged cabling or left in a state unsafe to approach
  • A condition you fixed yourself in under a minute, where the fix is temporary or the condition has appeared before

Do not use it for

  • Unsafe Act Report, which records a way of working that puts someone at risk, where the fault is method rather than plant.
  • Hazard Report, which records a source of harm identified proactively and feeds risk assessment, not a repair queue.
  • Housekeeping Deficiency Report, which handles untidiness, storage and general order where nothing has physically failed.
  • Stop Work Record, which is the instrument for halting an activity; this report documents the condition, not the decision.
  • Property Damage Report, which covers loss and damage to assets where no person was placed at risk.

Compliance mapping

Which ISO 45001 cl.6.1.2 requirements does this satisfy?

Each requirement below is tied to the section of the form that carries its evidence. Where more than one field applies, the section named is the one an auditor opens first.

ClauseRequirementWhere it lands
ISO 45001 cl.6.1.2Ongoing and proactive identification of hazards arising from infrastructure, equipment and physical workplace conditionsThe condition
ISO 45001 cl.5.4Mechanisms for workers to report hazardous situations without reprisal and be told the outcomeReport
ISO 45001 cl.8.1.2Application of the hierarchy of controls, with repair and engineering control preferred over administrative measuresResponse
ISO 45001 cl.10.2Reaction to a nonconformity, correction, and evaluation of the need for action to eliminate the causeResponse
ISO 45001 cl.5.3Assignment of responsibility and authority at the point where the work is doneResponse
ISO 45001 cl.7.5.3Documented information controlled and retrievable against the site and location it concernsWhere

What it does not cover

  • An email or verbal report to a supervisor, which carries no location, photograph or owner and cannot be retrieved when the condition recurs eleven months later.
  • A paper defect book at the line, which records but does not satisfy cl.9.1.1, because nothing in it can be counted, filtered by asset or trended.
  • The maintenance work order alone, which records the repair but not the risk, the urgency or whether the area was isolated.
  • A monthly inspection checklist, which is periodic by design and cannot demonstrate the ongoing identification cl.6.1.2 requires between inspections.
  • A CAPA raised after the fact, which documents the systemic response but leaves no evidence of who saw the condition, when, or in what state.

Global

Unsafe Condition Report requirements by country

Physical conditions are the most heavily prescribed area of safety law, because they are the easiest to inspect. Three regimes shape how this record is read.

Great Britain

Workplace (Health, Safety and Welfare) Regulations 1992, regs. 5, 8, 12 and 17; PUWER 1998, regs. 5 and 11

Duties on the physical state of workplace and work equipment, with maintenance as a continuing obligation rather than a scheduled task.

Reg. 5 requires the workplace and its equipment to be maintained in efficient working order and good repair, and expects a suitable system of maintenance. This log is the ordinary evidence such a system exists and reacts. Where the condition is a dangerous part of machinery, PUWER reg. 11 is effectively strict, and a report showing the guard was known defective and left in service is close to conclusive.

United States

29 CFR 1910.22, 1910.37(a), 1910.212(a) and OSH Act s.5(a)(1)

Condition-specific standards enforced by inspection, with the General Duty Clause covering recognised hazards no standard addresses.

Each standard is cited on what a compliance officer physically observes: obstructed exit routes, walking surfaces in disrepair, machines unguarded at the point of operation. Your own reports become recognition evidence under s.5(a)(1), and can turn a serious citation into a repeat one where the record shows the condition reported before and not durably corrected.

European Union

Directive 89/391/EEC, Arts. 6(3), 9(1)(a) and 13(2)(d); Directive 89/654/EEC on workplace requirements

A framework duty of continuous improvement, coupled with an explicit duty on the worker to report.

Art. 13(2)(d) obliges every worker to immediately inform the employer of any work situation presenting serious and immediate danger, and of shortcomings in the protection arrangements. Member State transpositions make that enforceable, so the employer must provide a route for it. A channel that is hard to reach, or visibly produces no response, undermines the Art. 6(3) risk evaluation.

How to complete it

How to complete an unsafe condition report, step by step

Four decisions inside this form determine whether the record defends the organisation or damages it. None are about typing.

Whether Urgency is set on consequence or on convenience

Urgency drives routing, so there is quiet pressure to under-rate anything that would wake somebody up. The honest test is not how bad the condition looks but what happens if nobody attends for the rest of the shift. If the answer involves anyone reaching past an unguarded part, walking the failed surface or using the obstructed exit, the rating is Immediate.

Whether Area Isolated is answered truthfully when Urgency is Immediate

This field appears only when Urgency is Immediate, and it is the most consequential answer in the form. No means the organisation identified a danger it called immediate and continued to expose people to it, and there is no version of that sentence that reads well in an investigation. If isolation genuinely was not possible, Condition Found must say what was done instead.

Whether Fixed Immediately reflects a durable repair or a hold

Yes should mean the condition is gone and will stay gone. A cable-tied guard, a cone over a floor defect or a taped-off panel are holding measures, and answering Yes for them removes the condition from every follow-up queue while leaving the hazard in place. The correct entry is No, with a work order raised and the interim measure noted.

Whether Action Required is judged on the condition or on its cause

The two fields are not duplicates. One asks whether the hazard has gone; the other asks whether the reason it appeared is still operating. A guard removed for cleaning every night, a lamp that fails monthly, a spill from a coupling never replaced — all warrant Yes and a CAPA reference, even where the fix took two minutes.

What auditors find

Most common unsafe condition report findings

These findings recur across audits of this record type, with the clause each engages and the change that closes it.

FindingClauseWhat fixes it
Reports are raised only for conditions that could not be fixed on the spot, so the log understates frequency by an order of magnitudeISO 45001 cl.9.1.1Make Fixed Immediately a normal outcome, not a reason to skip the form, and track reporting rate per area as a leading indicator.
Asset and Asset ID are blank on most records, defeating recurrence analysis by equipmentISO 45001 cl.6.1.2The Asset picker is filtered to the selected site, so the list is short. Require it where Condition Type is Damaged guard, and review blank rate monthly.
Urgency is set to Immediate but Area Isolated is answered No, with no explanation in the narrativeISO 45001 cl.8.1.2Route that combination to the area owner as an exception, and require a stated interim control in Condition Found before closure.
Work Order Raised is Yes but Work Order ID is never populated, breaking the link to maintenanceISO 45001 cl.10.2Work Order ID is conditional on Work Order Raised being Yes and links to the work order; make it required so closure cannot occur without the reference.
Photograph is taken after the condition is cleared, so the evidence shows a tidy floor rather than the hazardISO 45001 cl.7.5.3Train reporters to photograph before intervening where it is safe, and take any image of the corrected state as a second upload, not a replacement.
Records sit at Open indefinitely because the Area Owner named has left or never existedISO 45001 cl.5.3Area Owner is a user field, not free text. Maintain the area-to-owner mapping in the site register and audit the Overdue bucket weekly, not at management review.

Case in point

Case in point: the guard that was reported four times and repaired once

A chilled foods plant ran condition reporting on paper at the line. Over fourteen months the cutting room slicer had its interlock guard refitted repeatedly on night shift, each time inside fifteen minutes. Because the fix was quick and the line kept running, only one of those events produced a written record, closed as Fixed Immediately with no asset reference.

The interlock eventually failed open during wash-down and an operator reached into a moving blade. The investigation asked how often the guard had needed attention; the answer available to the company was once, while the fitters' recollection put it nearer a dozen. That gap was the finding — not that the guard was defective, but that nothing could notice it was chronically defective.

The template

The template, field by field

The form exactly as it installs. Every field, option, score and conditional rule is editable, and the links to other templates come with it.

24fields
4 sections
Reference
SAF-014
Archetype
Record
Record ID
CASE-2026-000
Scoring
Urgency band
Direction
High is bad
Singleton
No
Basis
ISO 45001 cl.6.1.2
Links
Feeds CAPA, work order
Tags
Hazard, Leading
Sections
4
Fields
24
Follow up fields
6
Repeating sections
0
Links out
4
Field typesOwn ID, generated on saveCase thread and parentPick list from a registryLinked to another templateFollow up, dashed outlineScored

Report

4 fields
Text

Case ID*

Generated on save

Auto sequence. Format CASE-2026-00000.

The record's own ID. Other templates point at this value.

Single Choice

Status*

Scored

Drives who this goes to next.

  • Planned2 pts
  • In progress2 pts
  • Complete3 pts
  • Deferred0 pts
  • Open0 pts
  • Closed3 pts
  • Overdue0 pts
Date & Time

Date and Time*

Users

Reported By*

Where

4 fields
Pick List

Site*

From FDN-001 Site NameFilter: Status is Active
Text

Site ID*

Linked

Format SITE-000.

Links to FDN-001 Site ID

Single Choice

Area*

The area within the site.

Cutting roomBoning hallPackingChill storeFreezerPasteurisingFillingCulture roomDespatchYardWorkshopPlant roomOffices
Location

Exact Location

Optional

Drop a pin for anything hard to find.

The condition

7 fields
Text

Condition Found*

File Upload

Photograph*

Single Choice

Condition Type*

Damaged guard, spill, poor lighting, blocked exit, damaged floor and so on.

Damaged guardSpillPoor lightingBlocked exitDamaged floor
Pick List

Asset

OptionalFrom FDN-002 Asset NameFilter: Site matches
Text

Asset ID

OptionalLinked

Format AST-0000.

Links to FDN-002 Asset ID

Single Choice

Urgency*

Immediate danger, this shift, this week or routine.

RoutineSoonImmediate
Single Choice

Area Isolated

OptionalShows if Urgency equals Immediate
YesNo

Response

9 fields
Single Choice

Fixed Immediately*

Scored
  • Yes2 pts
  • No0 pts
Single Choice

Work Order Raised

OptionalShows if Fixed Immediately equals No
YesNot neededNo
Text

Work Order ID

OptionalLinkedShows if Work Order Raised equals Yes

Links to MNT-002 Work Order ID

Single Choice

Action Required*

Scored

Raise the action record, then enter its reference here.

  • No2 pts
  • Yes0 pts
Single Choice

Priority

OptionalScoredShows if Action Required equals Yes
  • High0 pts
  • Medium1 pt
  • Low3 pts
Text

CAPA ID

OptionalLinkedShows if Action Required equals Yes

Format CAPA-2026-00000.

Links to FDN-014 CAPA ID

Users

Action Owner

OptionalShows if Action Required equals Yes
Users

Area Owner*

Signature

Signature*

SAF-014 · record IDs look like CASE-2026-000 · Feeds CAPA, work order

Open in Knowella

Run it with agents

From a document you fill in to a programme that runs itself

The form takes ninety seconds. The effort goes on routing each report to the right owner, chasing the ones that stall, and noticing when the same asset appears for the fifth time.

KnowSafe

Owns the report: routes on Urgency, escalates any Immediate record where Area Isolated is No, and holds the photograph and location against the case so evidence stays together through closure.

KnowMaintain

Picks up the maintenance half. Where Work Order Raised is Yes it carries the reference back into the report, and surfaces assets accumulating repeat conditions before failure becomes injury.

KnowContractor

Handles conditions created by or affecting contractors, so the report reaches the responsible firm's supervisor as well as your area owner rather than sitting in a queue they cannot see.

Ella
Ella

Watches the log across sites, flags recurrence by asset and area, drafts the CAPA where a pattern is established, and holds every write for your approval.

This template lives in KnowSafe — safety and compliance. Incidents, hazards, permits, inspections and the critical controls behind them.

Meet KnowSafe→

Glossary

Unsafe Condition Report definitions and key terms

Unsafe condition
A physical state of plant, structure or environment creating risk independently of how any person behaves around it.
Interim control
A temporary measure such as isolation, barriering or signage reducing exposure while a permanent repair is arranged. It never closes the condition.
Hierarchy of controls
The ranking in ISO 45001 cl.8.1.2 requiring elimination and engineering measures to be considered before administrative controls or PPE.
Recurrence
The reappearance of the same condition on the same asset or location — the only signal distinguishing a component fault from a random event.
Leading indicator
A measure taken before harm occurs, such as reports raised per area per month, judging whether the reporting system is alive rather than whether injuries fell.

FAQ

Frequently asked questions about unsafe condition report

Should a condition that was fixed in under a minute still be reported?+

Yes, and this behaviour alone determines whether the log is worth anything. The individual fix is trivial; the pattern is not. Fixed Immediately exists so a resolved condition can be logged in seconds without generating follow-up work.

What is the difference between raising a work order and raising a CAPA here?+

A work order restores the condition. A CAPA addresses why it arose and prevents its return. The fields are separate because most reports need one, some need neither, and recurring ones need both.

Who should be named as Area Owner?+

The person with budget and authority over the physical area — not the reporter, and not the maintenance planner. If one name covers every area on site, closure will bottleneck on that individual, which shows up quickly in the Overdue bucket.

Can this template be used for a near miss?+

No. If someone was nearly harmed, that is a Near Miss Report, which captures the sequence of events and the people involved. This record captures a state. Where both apply, raise the near miss and reference the condition report from it.

Is anonymous reporting supported?+

Reported By is a required user field, so the template as shipped is attributed. That is deliberate: it lets the reporter be told what happened, which is what sustains reporting rates.

How should the Area list be adapted?+

The shipped options reflect a food processing site. Replace them with your own areas before rollout, and keep the list short enough to pick one-handed on a phone. Exact Location covers anything the list cannot resolve.

Keep going

Related templates and programmes

Siddarth Singh

Written and reviewed by

Siddarth Singh

Founder & Chief Executive Officer, Knowella

Certified Safety Professional and industrial and systems engineer with more than a decade inside food supply chain, freight and manufacturing operations. This page was written against the current text of the standards it cites, not against secondary summaries of them.

  • Certified Safety Professional (CSP), Board of Certified Safety Professionals
  • MBA, University of Chicago Booth School of Business
  • MS and BS, The Ohio State University, Industrial and Systems Engineering
  • Six Sigma Black Belt
Verify with BCSP →

Sources and last review. Reviewed 16 August 2026 against:

  • ISO 45001:2018 — Occupational health and safety management systems, cl.6.1.2, cl.8.1.2, cl.10.2
  • Workplace (Health, Safety and Welfare) Regulations 1992 (SI 1992/3004), regs. 5, 8, 12, 17
  • Provision and Use of Work Equipment Regulations 1998 (SI 1998/2306), regs. 5 and 11
  • 29 CFR 1910.22, 1910.37(a), 1910.212(a); OSH Act 1970 s.5(a)(1)
  • Council Directive 89/391/EEC, Arts. 6(3), 9(1)(a), 13(2)(d)

This page is general guidance, not legal advice. Confirm requirements with your jurisdiction’s regulator.

Start in Minutes, Not Weeks

Launch a Ready-Made Template and Customize It Your Way

Every template is fully editable. Adjust fields, workflows, and branding to match your processes, then deploy to your team instantly.